SAB RailLine 560

continuously flexible SAB Rail Cable for outdoor use

Marking for SAB RailLine 560 65601105: 
SAB BRÖCKSKES · D-VIERSEN · SAB RailLine 560  5x0,75mm² C 6560-1105 CE

Marking for SAB RailLine 560 65601105: SAB BRÖCKSKES · D-VIERSEN · SAB RailLine 560 5x0,75mm² C 6560-1105 CE

Application

Flame-retardant and weather-resistant cable for flexible outdoor installation, e.g. bogie, railroad construction machines. This rail cable is also suitable for moving applications inside rail vehicles, e.g. door systems. This cable meets fire protection requirements with the highest hazard level - HL 1 to 3 - tested for indoor and outdoor use in accordance with EN 45545.

Outstanding features

  • weather resistant
  • continuously flexible
  • good ozone, UV and weather resistance
  • good oil and fuel resistance
  • fulfils fire protection requirements R15 (EL1A) and R16 (EL1B) acc. to EN 45545-2 for hazard levels HL1-3
  • flame retardant acc. to UN/ECE R118

Construction

Conductor

tinned copper strands, extra fine wires

Insulation

SABIX® X

Colour code

black cores with consecutive numbers

acc. to EN 50334 + VDE 0293-334,

green-yellow earth wire from 3 cores

Stranding

in layers resp. pairwise

Screen

tinned copper braiding (if existing)

Wrapping

foil

Sheath material

SABIX® X

Sheath colour

black (RAL 9005)

Conductor

tinned copper strands, extra fine wires

Insulation

SABIX® X

Colour code

black cores with consecutive numbers

acc. to EN 50334 + VDE 0293-334,

green-yellow earth wire from 3 cores

Stranding

in layers resp. pairwise

Screen

tinned copper braiding (if existing)

Wrapping

foil

Sheath material

SABIX® X

Sheath colour

black (RAL 9005)

Technical data

Nominal voltage

Uo/U 300/500 V resp. 0,6/1 kV

Testing voltage

300/500 V

core/core 2000 V

core/screen 2000 V

 

0,6/1 kV

core/core 4000 V

core/screen 4000 V

Min. bending radius

fixed laying: 4 x d

flexible application: 6 x d

continuously flexible: 10 x d

Torsion angle

± 15°/1 m

Temperature range

fixed laying: -50/+90 °C

flexible application: -50/+90 °C

Halogen-free

acc. to EN 50306-1 + EN 50264-1 are fulfilled.

Development of HCl is < 0,5%

acc. to IEC 60754-1.

pH-value is > 4,3 acc. to IEC 60754-2.

Conductivity is < 10,0 µS/mm acc. to IEC 60754-2.

Fluoric content < 0,1% acc. to IEC 60684-2.

Flame propagation

no flame propagation
acc. to IEC 60332-3-24 + VDE 0482-332-3-24
resp. IEC 60332-3-25 + VDE 0482-332-3-25 and EN 50305 + VDE 0260-305 section 9.1.2.

Flame retardant

acc. to ISO 6722 (UN/ECE R118)

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Toxicity

acc. to EN 50305 + VDE 0260-305

Smoke density

acc. to IEC 61034 + VDE 0482-1034

Weather resistance

very good

Oil and fuel resistance

acc. to EN 50264-1 + VDE 0260-264-1

Flexibility

very good

Absence of harmful substances

gemäß RoHS-Richtlinie der Europäischen Union

Nominal voltage

Uo/U 300/500 V resp. 0,6/1 kV

Testing voltage

300/500 V

core/core 2000 V

core/screen 2000 V

 

0,6/1 kV

core/core 4000 V

core/screen 4000 V

Min. bending radius

fixed laying: 4 x d

flexible application: 6 x d

continuously flexible: 10 x d

Torsion angle

± 15°/1 m

Temperature range

fixed laying: -50/+90 °C

flexible application: -50/+90 °C

Halogen-free

acc. to EN 50306-1 + EN 50264-1 are fulfilled.

Development of HCl is < 0,5%

acc. to IEC 60754-1.

pH-value is > 4,3 acc. to IEC 60754-2.

Conductivity is < 10,0 µS/mm acc. to IEC 60754-2.

Fluoric content < 0,1% acc. to IEC 60684-2.

Flame propagation

no flame propagation
acc. to IEC 60332-3-24 + VDE 0482-332-3-24
resp. IEC 60332-3-25 + VDE 0482-332-3-25 and EN 50305 + VDE 0260-305 section 9.1.2.

Flame retardant

acc. to ISO 6722 (UN/ECE R118)

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Toxicity

acc. to EN 50305 + VDE 0260-305

Smoke density

acc. to IEC 61034 + VDE 0482-1034

Weather resistance

very good

Oil and fuel resistance

acc. to EN 50264-1 + VDE 0260-264-1

Flexibility

very good

Absence of harmful substances

gemäß RoHS-Richtlinie der Europäischen Union

Dimensions

item no. Screened No. of cores x
cross section
Nominal voltage Outer-ø Copper figure Cable weight ≈
L65600002-2 x 0,50 mm²300/500 V4,9 mm9,6 kg/km37 kg/km Send inquiry
L65600105-5 x 0,75 mm²300/500 V6,4 mm36,0 kg/km73 kg/km Send inquiry
L65600203-3 x 1,00 mm²300/500 V5,3 mm28,8 kg/km55 kg/km Send inquiry
L65600205-5 x 1,00 mm²300/500 V6,7 mm48,0 kg/km86 kg/km Send inquiry
L65600207-7 x 1,00 mm²300/500 V7,9 mm67,2 kg/km127 kg/km Send inquiry
L65600225-25 x 1,00 mm²300/500 V13,4 mm240,0 kg/km346 kg/km Send inquiry
L65600304-4 x 1,50 mm²300/500 V6,9 mm57,6 kg/km101 kg/km Send inquiry
L65600307-7 x 1,50 mm²300/500 V9,3 mm100,8 kg/km175 kg/km Send inquiry
L65609001-5 x 35,00 mm²0,6/1 kV33,2 mm1680,0 kg/km2299 kg/km Send inquiry
L65601002X2 x 0,50 mm²300/500 V4,9 mm24,7 kg/km42 kg/km Send inquiry
L65601003X3 x 0,50 mm²300/500 V5,3 mm29,7 kg/km51 kg/km Send inquiry
L65601005X5 x 0,50 mm²300/500 V6,1 mm40,2 kg/km67 kg/km Send inquiry
L65601012X12 x 0,50 mm²300/500 V8,5 mm85,9 kg/km132 kg/km Send inquiry
L65601105X5 x 0,75 mm²300/500 V6,8 mm53,6 kg/km87 kg/km Send inquiry
L65601204X4 x 1,00 mm²300/500 V6,6 mm57,0 kg/km86 kg/km Send inquiry
L65601213X13 x 1,00 mm²300/500 V10,8 mm169,2 kg/km235 kg/km Send inquiry
L65601303X3 x 1,50 mm²300/500 V7,3 mm63,4 kg/km99 kg/km Send inquiry
L65601305X5 x 1,50 mm²300/500 V8,3 mm94,6 kg/km152 kg/km Send inquiry
L65601307X7 x 1,50 mm²300/500 V9,7 mm127,4 kg/km195 kg/km Send inquiry
L65609002X5 x 35,00 mm²0,6/1 kV34,1 mm1885,3 kg/km2455 kg/km Send inquiry
L65609004X6 x 2 x 0,25 mm²300/500 V8,0 mm46,3 kg/km98 kg/km Send inquiry
L65609005X12 x 2 x 0,34 mm²300/500 V11,9 mm131,4 kg/km204 kg/km Send inquiry
L65603002X2 x 2 x 0,50 mm²300/500 V6,7 mm35,5 kg/km69 kg/km Send inquiry
L65603004X4 x 2 x 0,50 mm²300/500 V8,5 mm60,1 kg/km108 kg/km Send inquiry
L65603006X8 x 2 x 0,50 mm²300/500 V12,3 mm129,3 kg/km230 kg/km Send inquiry
L65603103X3 x 2 x 0,75 mm²300/500 V8,4 mm65,9 kg/km124 kg/km Send inquiry
item no.
Screened
No. of cores x
cross section
Nominal voltage
Outer-ø
Copper figure
Cable weight ≈
L65600002
-
2 x 0,50 mm²
300/500 V
4,9 mm
9,6 kg/km
37 kg/km
L65600105
-
5 x 0,75 mm²
300/500 V
6,4 mm
36,0 kg/km
73 kg/km
L65600203
-
3 x 1,00 mm²
300/500 V
5,3 mm
28,8 kg/km
55 kg/km
L65600205
-
5 x 1,00 mm²
300/500 V
6,7 mm
48,0 kg/km
86 kg/km
L65600207
-
7 x 1,00 mm²
300/500 V
7,9 mm
67,2 kg/km
127 kg/km
L65600225
-
25 x 1,00 mm²
300/500 V
13,4 mm
240,0 kg/km
346 kg/km
L65600304
-
4 x 1,50 mm²
300/500 V
6,9 mm
57,6 kg/km
101 kg/km
L65600307
-
7 x 1,50 mm²
300/500 V
9,3 mm
100,8 kg/km
175 kg/km
L65609001
-
5 x 35,00 mm²
0,6/1 kV
33,2 mm
1680,0 kg/km
2299 kg/km
L65601002
X
2 x 0,50 mm²
300/500 V
4,9 mm
24,7 kg/km
42 kg/km
L65601003
X
3 x 0,50 mm²
300/500 V
5,3 mm
29,7 kg/km
51 kg/km
L65601005
X
5 x 0,50 mm²
300/500 V
6,1 mm
40,2 kg/km
67 kg/km
L65601012
X
12 x 0,50 mm²
300/500 V
8,5 mm
85,9 kg/km
132 kg/km
L65601105
X
5 x 0,75 mm²
300/500 V
6,8 mm
53,6 kg/km
87 kg/km
L65601204
X
4 x 1,00 mm²
300/500 V
6,6 mm
57,0 kg/km
86 kg/km
L65601213
X
13 x 1,00 mm²
300/500 V
10,8 mm
169,2 kg/km
235 kg/km
L65601303
X
3 x 1,50 mm²
300/500 V
7,3 mm
63,4 kg/km
99 kg/km
L65601305
X
5 x 1,50 mm²
300/500 V
8,3 mm
94,6 kg/km
152 kg/km
L65601307
X
7 x 1,50 mm²
300/500 V
9,7 mm
127,4 kg/km
195 kg/km
L65609002
X
5 x 35,00 mm²
0,6/1 kV
34,1 mm
1885,3 kg/km
2455 kg/km
L65609004
X
6 x 2 x 0,25 mm²
300/500 V
8,0 mm
46,3 kg/km
98 kg/km
L65609005
X
12 x 2 x 0,34 mm²
300/500 V
11,9 mm
131,4 kg/km
204 kg/km
L65603002
X
2 x 2 x 0,50 mm²
300/500 V
6,7 mm
35,5 kg/km
69 kg/km
L65603004
X
4 x 2 x 0,50 mm²
300/500 V
8,5 mm
60,1 kg/km
108 kg/km
L65603006
X
8 x 2 x 0,50 mm²
300/500 V
12,3 mm
129,3 kg/km
230 kg/km
L65603103
X
3 x 2 x 0,75 mm²
300/500 V
8,4 mm
65,9 kg/km
124 kg/km

Other dimensions and colours are possible on request.

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30