Technical Description of measuring insert for thermocouples
The following measuring insert for thermocouples are available as thermocouples:
- thermocouple:
1 x Typ K or 2 x Typ K
1 x Typ J or 2 x Typ J
1 x Typ L or 2 x Typ L - limit deviation: class 1 or 2 acc. to DIN EN 60584 for types K and J
- limit deviation: with reference to DIN 43710 for type L
- sheath: ø 1,5 mm; ø 3,0 mm; ø 4,5 mm; ø 6,0 mm or 6,0 mm with measuring tip ø 8,0 mm
- transmitter: with 1 or 2 transmitters
The following gauge slides are available as resistance thermometers:
- resistance thermometer: 1 x Pt 100 or 2 x Pt 100 in 2-, 3-, 4-wire circuit
- temperature range: -50°C/+400°C or -50°C/+600°C
- limit deviation: class A or B acc. to DIN EN 60751
- sheath: ø 1,6 mm; ø 3,0 mm; ø 4,5 mm; ø 6,0 mm or 6,0 mm with measuring tip ø 8,0 mm
- transmitter: with one or two transmitters
Every gauge slide manufactured at SAB has a type plate at its lower side indicating for example:
- SAB item no: T 752-041-724
- type/number of thermocouples: 2 x type K
- temperature range: -40°C / +1100°C
- SAB work order no.: T084815
- week and year of production: 37/07
- accuracy
Do you have any questions about our products? Your direct line to our experts! Contact