Application
SABIX® A 147 FRNC is a flame retardant, halogen-free wiring cable with a voltage of 600 V. This electrical cable with UL is recommended for use in production of control cabinets, appliances and devices for communication technologies, household appliances, construction of generators and transformers, machine construction, and railway technologies: furthermore, the FRNC type is particulary suitable for internal wiring of rail vehicles.
The core cable is also available with tinned copper strands on request.
Outstanding features
- halogen-free
- no flame propagation
- flame retardant and self-extinguishing
- UL recognized
Additional information
* Colour code for the single wire/core line can be selected as follows:
Colour code | Colour | Colour code | Colour |
01 = | black | 06 = | green |
02 = | blue | 07 = | purple |
03 = | brown | 08 = | white |
04 = | grey | 16 = | gentian blue |
05 = | yellow | 27 = | green/yellow |
Color code for single cores/leads
Construction
Conductor | tinned copper strands acc. to IEC 60228, VDE 0295, class 5 |
---|---|
Insulation | SABIX® |
Colour code | see table*additional information |
tinned copper strands acc. to IEC 60228, VDE 0295, class 5
SABIX®
see table*additional information
Technical data
Nominal voltage | 0,50 - 1,0 mm²: Uo/U 300/500 V |
---|---|
Voltage UL | 20 - 18 AWG: 600 V |
Testing voltage | 2000 V |
Min. bending radius | 7,5 x d For one single bend: 5 x d |
Temperature range | DIN VDE fixed laying: -40/+90 °C DIN VDE flexible application: -30/+90 °C UL: up to +75°C |
Halogen-free | acc. to IEC 60754-1 + VDE 0482-754-1 |
Flame propagation | no flame propagation |
Fire performance | flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 |
Corrosiveness of conflagration gases | in compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases |
Smoke density | acc. to IEC 61034 + VDE 0482-1034 |
Flexibility | good |
Absence of harmful substances | acc. to RoHS directive of the European Union |
0,50 - 1,0 mm²: Uo/U 300/500 V
20 - 18 AWG: 600 V
2000 V
7,5 x d
For one single bend:
5 x d
DIN VDE fixed laying: -40/+90 °C
DIN VDE flexible application: -30/+90 °C
UL: up to +75°C
acc. to IEC 60754-1 + VDE 0482-754-1
no flame propagation
acc. to IEC 60332-3-24 + VDE 0482-332-3-24
resp. IEC 60332-3-25 + VDE 0482-332-3-25 category C resp. D
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2
in compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases
acc. to IEC 61034 + VDE 0482-1034
good
acc. to RoHS directive of the European Union
Dimensions
item no. |
Nominal cross section | AWG/ MCM |
Largest single wire-ø | Outer-ø ± 5% | Copper figure | Cable weight ≈ | |
---|---|---|---|---|---|---|---|
L6147 .. 50* | 0,5 mm² | 20 (15/32) | 0,21 mm | 2,5 mm | 4,8 kg/km | 12 kg/km | Send inquiry |
L6147 .. 75* | 0,75 mm² | 19 (23/32) | 0,21 mm | 2,8 mm | 7,2 kg/km | 14 kg/km | Send inquiry |
L6147 .. 80* | 1 mm² | 18 (30/32) | 0,21 mm | 2,9 mm | 9,6 kg/km | 16 kg/km | Send inquiry |
section
wire-ø
Other dimensions and colours are possible on request.