S CB 626
CAN-bus cable for cable tracks
Application
The CAN bus cable for cable tracks has FEP core insulation and very good oil resistance. It is used in the exchange of digital information, Controller Area Network (CAN), for faster data transmission.
Outstanding features
- suitable for cable tracks
- very good oil resistance
- good chemical resistance
- very good weather resistance
- fast data transmission
Construction
Conductor | bare copper strands, fine wires |
---|---|
Insulation | FEP |
Colour code | with reference to DIN 47100 |
Wrapping | non-woven tape |
Screen | tinned copper braiding |
Wrapping | non-woven tape |
Sheath material | PUR, TMPU acc. to EN 50363-10-2 with rough surface |
Sheath colour | redlilac (RAL 4001) |
bare copper strands, fine wires
FEP
with reference to DIN 47100
non-woven tape
tinned copper braiding
non-woven tape
PUR, TMPU acc. to EN 50363-10-2 with rough surface
redlilac (RAL 4001)
Technical data
Peak operating voltage | max. 350 V |
---|---|
Testing voltage | core/core: 1500V core/screen: 1200V |
Min. bending radius | 7,5 x d |
Radiation resistance | 5 x 10^7 cJ/kg |
Temperature range | fixed laying: -50/+90°C flexible application: -40/+90°C |
Oil resistance | very good - acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
Chem. resistance | good against acids, alkalines, solvents, hydraulic liquids etc. |
Characteristic impedance | 120 Ω (95 - 140 Ω) |
Flexibility | very good |
Application in cable tracks | recommended |
Weather resistance | very good |
Bending characteristics | number of bendings acc. to VDE 0472 part 603 test methode H min. 250.000 single bendings |
Absence of harmful substances | acc. to RoHS directive of the European Union |
max. 350 V
core/core: 1500V
core/screen: 1200V
7,5 x d
5 x 10^7 cJ/kg
fixed laying: -50/+90°C
flexible application: -40/+90°C
very good - acc. to EN 50363-10-2 + VDE 0207-363-10-2
good against acids, alkalines, solvents, hydraulic liquids etc.
120 Ω (95 - 140 Ω)
very good
recommended
very good
number of bendings acc. to VDE 0472 part 603 test methode H
min. 250.000 single bendings
acc. to RoHS directive of the European Union
Dimensions
item no. | Dimension | Copper figure | Cable weight ≈ | Outer-ø ± 5% | |
---|---|---|---|---|---|
L06262251 | 2 x 0,25 mm² | 20,8 kg/km | 49 kg/km | 6,2 mm | Send inquiry |
Other dimensions and colours are possible on request.