B 110 C

Highly flexible Besilen® insulated UL HV single core, shielded, cULus recognized

Marking for B 110 C 01109507: SAB BRÖCKSKES · D-VIERSEN · B 110 C  Uo/U 1,8/3 kV 95,0mm² cULus AWM Style 30123 AWM I/II A/B 150°C 3000V FT1 FT2

Marking for B 110 C 01109507: SAB BRÖCKSKES · D-VIERSEN · B 110 C Uo/U 1,8/3 kV 95,0mm² cULus AWM Style 30123 AWM I/II A/B 150°C 3000V FT1 FT2

Application

HV cable or high-voltage connection cable is ideal for connecting inverters to e-mobility test benches, for example. Due to the high voltage classes, the HV cable can be used for various components and power electronics. Thanks to its highly flexible design, the high-voltage cable is very easy to install.

Outstanding features

  • extremely flexible
  • good EMC characteristics
  • halogen-free
  • heat resistant
  • flexible at low temperatures
  • flame retardant and self-extinguishing
  • weather resistant
  • cULus recognized

Construction

Conductor

bare copper strands, extra fine wires

Insulation

Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1, orange

Screen

alu foil and tinned copper braiding

Sheath material

Besilen® EM9 acc. to EN 50363-2-1 + VDE 0207-363-2-1

Sheath colour

orange (similar RAL 2004)

Conductor

bare copper strands, extra fine wires

Insulation

Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1, orange

Screen

alu foil and tinned copper braiding

Sheath material

Besilen® EM9 acc. to EN 50363-2-1 + VDE 0207-363-2-1

Sheath colour

orange (similar RAL 2004)

Technical data

Nominal voltage

Uo/U 1,8/3,0 kV AC

Uo/U 2,7/5,4 kV DC

Voltage cULus

3000 V

Testing voltage

6500 V

Current-carrying capacity

acc. to VDE 0298-4

Min. bending radius

fixed laying: 3 x d

flexible application: 6 x d

Temperature range

fixed laying: -50/+180 °C

flexible application: -25/+180 °C

short-time use: +250 °C

cULus: up to +150 °C

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, cULus FT1, FT2

Corrosiveness of conflagration gases

IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases

Weather resistance

very good

Absence of harmful substances

acc. to RoHS directive of the European Union

Nominal voltage

Uo/U 1,8/3,0 kV AC

Uo/U 2,7/5,4 kV DC

Voltage cULus

3000 V

Testing voltage

6500 V

Current-carrying capacity

acc. to VDE 0298-4

Min. bending radius

fixed laying: 3 x d

flexible application: 6 x d

Temperature range

fixed laying: -50/+180 °C

flexible application: -25/+180 °C

short-time use: +250 °C

cULus: up to +150 °C

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, cULus FT1, FT2

Corrosiveness of conflagration gases

IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases

Weather resistance

very good

Absence of harmful substances

acc. to RoHS directive of the European Union

Dimensions

item no. Nominal cross
section
Largest single
wire-ø
ø over inner sheath approx. mm Copper figure Cable weight ≈ Outer-ø ± 5%
L011001071,00 mm²0,07 mm4,3 mm27,2 kg/km70 kg/km7,6 mm Send inquiry
L011001571,50 mm²0,07 mm4,7 mm34,4 kg/km81 kg/km8,0 mm Send inquiry
L011002572,50 mm²0,07 mm5,2 mm44,6 kg/km96 kg/km8,5 mm Send inquiry
L011004074 mm²0,07 mm5,9 mm61,3 kg/km118 kg/km9,2 mm Send inquiry
L011006076 mm²0,07 mm6,3 mm83,8 kg/km143 kg/km9,6 mm Send inquiry
L0110100710 mm²0,07 mm8,2 mm147,7 kg/km222 kg/km11,7 mm Send inquiry
L0110160716 mm²0,07 mm8,5 mm205,7 kg/km273 kg/km12,0 mm Send inquiry
L0110250725 mm²0,1 mm11,2 mm307,4 kg/km416 kg/km14,7 mm Send inquiry
L0110350735 mm²0,1 mm12,6 mm432,6 kg/km548 kg/km16,3 mm Send inquiry
L0110500750 mm²0,1 mm14,5 mm593,6 kg/km725 kg/km18,2 mm Send inquiry
L0110700770 mm²0,1 mm16,5 mm804,4 kg/km954 kg/km20,4 mm Send inquiry
L0110950795 mm²0,1 mm18,4 mm1064,5 kg/km1244 kg/km22,3 mm Send inquiry
L01101207120 mm²0,1 mm20,1 mm1311,0 kg/km1514 kg/km24,2 mm Send inquiry
L01101507150 mm²0,1 mm23,3 mm1627,6 kg/km1873 kg/km27,4 mm Send inquiry
L01101857185 mm²0,15 mm24,9 mm1970,9 kg/km2231 kg/km29,2 mm Send inquiry
L01102407240 mm²0,15 mm27,5 mm2511,2 kg/km2841 kg/km32,0 mm Send inquiry
L01103007300 mm²0,15 mm30,0 mm3108,6 kg/km3354 kg/km34,7 mm Send inquiry
item no.
Nominal cross
section
Largest single
wire-ø
ø over inner sheath approx. mm
Copper figure
Cable weight ≈
Outer-ø ± 5%
L01100107
1,00 mm²
0,07 mm
4,3 mm
27,2 kg/km
70 kg/km
7,6 mm
L01100157
1,50 mm²
0,07 mm
4,7 mm
34,4 kg/km
81 kg/km
8,0 mm
L01100257
2,50 mm²
0,07 mm
5,2 mm
44,6 kg/km
96 kg/km
8,5 mm
L01100407
4 mm²
0,07 mm
5,9 mm
61,3 kg/km
118 kg/km
9,2 mm
L01100607
6 mm²
0,07 mm
6,3 mm
83,8 kg/km
143 kg/km
9,6 mm
L01101007
10 mm²
0,07 mm
8,2 mm
147,7 kg/km
222 kg/km
11,7 mm
L01101607
16 mm²
0,07 mm
8,5 mm
205,7 kg/km
273 kg/km
12,0 mm
L01102507
25 mm²
0,1 mm
11,2 mm
307,4 kg/km
416 kg/km
14,7 mm
L01103507
35 mm²
0,1 mm
12,6 mm
432,6 kg/km
548 kg/km
16,3 mm
L01105007
50 mm²
0,1 mm
14,5 mm
593,6 kg/km
725 kg/km
18,2 mm
L01107007
70 mm²
0,1 mm
16,5 mm
804,4 kg/km
954 kg/km
20,4 mm
L01109507
95 mm²
0,1 mm
18,4 mm
1064,5 kg/km
1244 kg/km
22,3 mm
L01101207
120 mm²
0,1 mm
20,1 mm
1311,0 kg/km
1514 kg/km
24,2 mm
L01101507
150 mm²
0,1 mm
23,3 mm
1627,6 kg/km
1873 kg/km
27,4 mm
L01101857
185 mm²
0,15 mm
24,9 mm
1970,9 kg/km
2231 kg/km
29,2 mm
L01102407
240 mm²
0,15 mm
27,5 mm
2511,2 kg/km
2841 kg/km
32,0 mm
L01103007
300 mm²
0,15 mm
30,0 mm
3108,6 kg/km
3354 kg/km
34,7 mm

Other dimensions and colours are possible on request.

Measurement technology specifically for your application.

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00