HV 1000 C - SC

robust, flexible high-voltage single conductor with overall copper screen

Marking for HV 1000 C SC 39100163: SAB BRÖCKSKES · D-VIERSEN · HV 1000 C - SC  1x25mm² 3910-0163  CE

Marking for HV 1000 C SC 39100163: SAB BRÖCKSKES · D-VIERSEN · HV 1000 C - SC 1x25mm² 3910-0163 CE

Application

These high-voltage cables can be used in high-voltage applications e.g. in the fields of agricultural vehicles, construction vehicles and special vehicles. The HV 1000 C - SC is used e.g. between inverters and electric motors.

Outstanding features

  • extremely high mechanical strength
  • high protection against environmental influences
  • 100% oil resistance acc. to standard
  • application range from -50°C to +125°C

Additional information

Construction, materials and tests with reference to:
●  DIN EN 60228
●  DIN EN 50525
●  DIN EN 50290-2-30
●  DIN EN 50620
●  DIN EN 60811
In individual cases, the specific application must be agreed with SAB Bröckskes.

Construction

Conductor

bare copper strands, extra fine wires

Insulation

TPFP

Colour code

orange

Screen

alu foil and tinned copper braiding

Wrapping

non-woven tape

Sheath material

TPE-U

Sheath colour

orange (RAL 2003)

Conductor

bare copper strands, extra fine wires

Insulation

TPFP

Colour code

orange

Screen

alu foil and tinned copper braiding

Wrapping

non-woven tape

Sheath material

TPE-U

Sheath colour

orange (RAL 2003)

Technical Data

Nominal voltage

Uo/U max. 0,6/1 kV AC/DC

Testing voltage

core/screen 5000 V

Min. bending radius

fixed laying: 5 x d

flexible application: 10 x d

Temperature range

fixed laying: -50/+90 °C

flexible application: -40/+90 °C

limited time of use: +125 °C (2000 h)

Low temperature resistance

-50°C acc. to DIN EN 60811-506

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Oil resistance

very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2

MUD resistance:

very good - acc. to IEC 60092-360, IEC 61892-4, NEK TS 606

UV resistance

acc. to HD 605

Ozone resistance

acc. to EN 50396

Saltwater resistance

acc. to UL 1309

Mechanical characteristics

the main mechanical characteristics accomplished by the outer sheath are:

- high tensile strength

- high tear strength

- high abrasion resistance

- high notch resistance

- high shear strength

Absence of harmful substances

acc. to RoHS directive of the European Union

Nominal voltage

Uo/U max. 0,6/1 kV AC/DC

Testing voltage

core/screen 5000 V

Min. bending radius

fixed laying: 5 x d

flexible application: 10 x d

Temperature range

fixed laying: -50/+90 °C

flexible application: -40/+90 °C

limited time of use: +125 °C (2000 h)

Low temperature resistance

-50°C acc. to DIN EN 60811-506

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

MUD resistance:

very good - acc. to IEC 60092-360, IEC 61892-4, NEK TS 606

UV resistance

acc. to HD 605

Ozone resistance

acc. to EN 50396

Saltwater resistance

acc. to UL 1309

Mechanical characteristics

the main mechanical characteristics accomplished by the outer sheath are:

- high tensile strength

- high tear strength

- high abrasion resistance

- high notch resistance

- high shear strength

Absence of harmful substances

acc. to RoHS directive of the European Union

Dimensions

item no. Nominal cross
section
Largest single
wire-ø
max. outer-ø Copper figure Cable weight ≈ Ohmic resistance
at 20°C max.
L391001606,00 mm²0,21 mm6,5 mm85,5 kg/km99 kg/km3,30 Ω/km Send inquiry
L3910016110,00 mm²0,21 mm8,8 mm134,5 kg/km172 kg/km1,91 Ω/km Send inquiry
L3910016216,00 mm²0,21 mm10,2 mm201,0 kg/km246 kg/km1,21 Ω/km Send inquiry
L3910016325,00 mm²0,21 mm12,2 mm317,2 kg/km363 kg/km0,78 Ω/km Send inquiry
L3910016435,00 mm²0,21 mm14,4 mm427,4 kg/km506 kg/km0,554 Ω/km Send inquiry
L3910016550,00 mm²0,21 mm15,8 mm586,3 kg/km671 kg/km0,386 Ω/km Send inquiry
L3910016670,00 mm²0,21 mm18,2 mm796,7 kg/km900 kg/km0,227 Ω/km Send inquiry
L3910016795,00 mm²0,21 mm20,9 mm1097,7 kg/km1212 kg/km0,206 Ω/km Send inquiry
L391001404,00 mm²0,21 mm5,8 mm63,2 kg/km75 kg/km4,95 Ω/km Send inquiry
item no.
Nominal cross
section
Largest single
wire-ø
max. outer-ø
Copper figure
Cable weight ≈
Ohmic resistance
at 20°C max.
L39100160
6,00 mm²
0,21 mm
6,5 mm
85,5 kg/km
99 kg/km
3,30 Ω/km
L39100161
10,00 mm²
0,21 mm
8,8 mm
134,5 kg/km
172 kg/km
1,91 Ω/km
L39100162
16,00 mm²
0,21 mm
10,2 mm
201,0 kg/km
246 kg/km
1,21 Ω/km
L39100163
25,00 mm²
0,21 mm
12,2 mm
317,2 kg/km
363 kg/km
0,78 Ω/km
L39100164
35,00 mm²
0,21 mm
14,4 mm
427,4 kg/km
506 kg/km
0,554 Ω/km
L39100165
50,00 mm²
0,21 mm
15,8 mm
586,3 kg/km
671 kg/km
0,386 Ω/km
L39100166
70,00 mm²
0,21 mm
18,2 mm
796,7 kg/km
900 kg/km
0,227 Ω/km
L39100167
95,00 mm²
0,21 mm
20,9 mm
1097,7 kg/km
1212 kg/km
0,206 Ω/km
L39100140
4,00 mm²
0,21 mm
5,8 mm
63,2 kg/km
75 kg/km
4,95 Ω/km

Other dimensions and colours are possible on request.

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00