Application
These high-voltage cables can be used in high-voltage applications e.g. in the fields of agricultural vehicles, construction vehicles and special vehicles. The HV 1000 C - MC is used as a connection cable e.g. for cabin heating, the electric compressor, the high-voltage heat pump in electric and hybrid vehicles.
Outstanding features
- extremely high mechanical strength
- high protection against environmental influences
- 100% oil resistance acc. to standard
- application range from -50°C to +125°C
Additional information
Construction, materials and tests with reference to:
● DIN EN 60228
● DIN EN 50525
● DIN EN 50290-2-30
● DIN EN 50620
● DIN EN 60811
In individual cases, the specific application must be agreed with SAB Bröckskes.
Construction
Conductor | bare copper strands acc. to IEC 60228, VDE 0295, class 5 |
---|---|
Insulation | TPFP |
Colour code | red, black, from 3 cores acc. to HD 308 or acc. to customer request |
Stranding | together |
Inner sheath | Besilen® |
Screen | alu foil and tinned copper braiding |
Wrapping | non-woven tape |
Sheath material | TPE-U |
Sheath colour | orange (RAL 2003) |
bare copper strands acc. to IEC 60228, VDE 0295, class 5
TPFP
red, black,
from 3 cores acc. to HD 308
or acc. to customer request
together
Besilen®
alu foil and tinned copper braiding
non-woven tape
TPE-U
orange (RAL 2003)
Technical Data
Nominal voltage | Uo/U max. 0,6/1 kV AC/DC |
---|---|
Testing voltage | core/core 5000 V core/screen 5000 V |
Min. bending radius | fixed laying: 5 x d flexible application: 10 x d |
Temperature range | fixed laying: -50/+90 °C flexible application: -40/+90 °C limited time of use: +125 °C (2000 h) |
Low temperature resistance | -50°C acc. to DIN EN 60811-506 |
Fire performance | flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 |
Oil resistance | very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
MUD resistance | very good - acc. to IEC 60092-360, IEC 61892-4, NEK TS 606 |
UV resistance | acc. to HD 605 |
Ozone resistance | acc. to EN 50396 |
Saltwater resistance | acc. to UL 1309 |
Mechanical characteristics | the main mechanical characteristics accomplished by the outer sheath are: - high tensile strength - high tear strength - high abrasion resistance - high notch resistance - high shear strength |
Absence of harmful substances | acc. to RoHS directive of the European Union |
Uo/U max. 0,6/1 kV AC/DC
core/core 5000 V
core/screen 5000 V
fixed laying: 5 x d
flexible application: 10 x d
fixed laying: -50/+90 °C
flexible application: -40/+90 °C
limited time of use: +125 °C (2000 h)
-50°C acc. to DIN EN 60811-506
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2
very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2
very good - acc. to IEC 60092-360, IEC 61892-4, NEK TS 606
acc. to HD 605
acc. to EN 50396
acc. to UL 1309
the main mechanical characteristics accomplished by the outer sheath are:
- high tensile strength
- high tear strength
- high abrasion resistance
- high notch resistance
- high shear strength
acc. to RoHS directive of the European Union
Dimensions
item no. |
No. of cores x cross section |
Largest single wire-ø | max. outer-ø | Copper figure | Cable weight ≈ |
Ohmic resistance max. Ω/km | |
---|---|---|---|---|---|---|---|
L39100225 | 2 x 2,50 mm² | 0,26 mm | 9,9 mm | 93,4 kg/km | 147 kg/km | 7,98 Ω/km | Send inquiry |
L39100325 | 3 x 2,50 mm² | 0,26 mm | 10,4 mm | 117,3 kg/km | 181 kg/km | 7,98 Ω/km | Send inquiry |
L39100240 | 2 x 4,00 mm² | 0,31 mm | 11,3 mm | 133,7 kg/km | 206 kg/km | 4,95 Ω/km | Send inquiry |
L39100340 | 3 x 4,00 mm² | 0,31 mm | 12,1 mm | 171,5 kg/km | 252 kg/km | 4,95 Ω/km | Send inquiry |
L39100260 | 2 x 6,00 mm² | 0,31 mm | 12,8 mm | 175,8 kg/km | 266 kg/km | 3,10 Ω/km | Send inquiry |
L39100360 | 3 x 6,00 mm² | 0,31 mm | 14,1 mm | 261,3 kg/km | 366 kg/km | 3,10 Ω/km | Send inquiry |
L39100460 | 4 x 6,00 mm² | 0,31 mm | 15,1 mm | 325,3 kg/km | 433 kg/km | 3,10 Ω/km | Send inquiry |
L39100560 | 5 x 6,00 mm² | 0,31 mm | 16,3 mm | 393,5 kg/km | 515 kg/km | 3,10 Ω/km | Send inquiry |
cross section
wire-ø
max. Ω/km
Other dimensions and colours are possible on request.