Construction
Conductor | bare copper strands, extra fine wires, class 6 acc. to IEC 60228 |
---|---|
Insulation | SABIX® |
Colour code | L0390-9696: DIN 47100 1-10 L0390-9721: black cores with consecutive numbers 1 - 12 |
Stranding | cores twisted to pairs + optimized twisting of pairs in layers, filler in centre |
Screen | laminated alu foil with overlap wrapping, tinned copper braiding, optical coverage ≥ 85% |
Banding | overlapping non-woven tape |
Sheath material | PUR |
Sheath colour | black (similar RAL 9005) |
bare copper strands, extra fine wires, class 6 acc. to IEC 60228
SABIX®
L0390-9696: DIN 47100 1-10
L0390-9721: black cores with consecutive numbers 1 - 12
cores twisted to pairs + optimized twisting of pairs in layers, filler in centre
laminated alu foil with overlap wrapping, tinned copper braiding, optical coverage ≥ 85%
overlapping non-woven tape
PUR
black (similar RAL 9005)
Technical Data
Peak operating voltage | max. 350 V |
---|---|
Testing voltage | core/core 1500 V core/screen 1200 V |
Min. bending radius | fixed laying: 5 x d flexible application: 10 x d |
Temperature range | fixed laying: -50/+90 °C flexible application: -40/+90 °C limited time of use: +125 °C (2000 h) |
Low temperature resistance | -50°C acc. to DIN EN 60811-506 |
Fire performance | acc. to IEC 60332-1-2 |
Halogen-free | acc. to IEC 60754-1 |
Oil resistance | very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
MUD resistance | very good - acc. to IEC 60092-360, IEC 61892-4, NEK TS 606 |
UV resistance | acc. to HD 605 S1 |
Ozone resistance | acc. to DIN EN 50396 |
Saltwater resistance | acc. to UL 1309 |
Mechanical characteristics by the outer sheath | - high tensile strength - high tear strength - high abrasion resistance - high notch resistance - high shear strength |
Absence of harmful substances | acc. to RoHS directive of the European Union |
max. 350 V
core/core 1500 V
core/screen 1200 V
fixed laying: 5 x d
flexible application: 10 x d
fixed laying: -50/+90 °C
flexible application: -40/+90 °C
limited time of use: +125 °C (2000 h)
-50°C acc. to DIN EN 60811-506
acc. to IEC 60332-1-2
acc. to IEC 60754-1
very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2
very good - acc. to IEC 60092-360, IEC 61892-4, NEK TS 606
acc. to HD 605 S1
acc. to DIN EN 50396
acc. to UL 1309
- high tensile strength
- high tear strength
- high abrasion resistance
- high notch resistance
- high shear strength
acc. to RoHS directive of the European Union
Dimensions
item no. | Approx. core-ø | Conductor-ø | Copper figure | Cable weight ≈ |
Ohmic resistance at 20°C max. | |
---|---|---|---|---|---|---|
L0390-9696 | 1,5 mm | 1,00 mm | 77,8 kg/km | 104 kg/km | 39,0 Ω/km | Send inquiry |
L0390-9721 | 1,5 mm | 1,00 mm | 85,5 kg/km | 118 kg/km | 39,0 Ω/km | Send inquiry |
at 20°C max.