Application
Safe HV temperature measurement in HV environments
Additional information
Issue of HV test certificate with reference to batch number due to optimum traceability.
Optional: Test and repair of already used sensors on request.
SAB identification: item number, batch number
Cable data 1 x 8 cores
Designation | HV measuring cable – 1 x 8 cores |
---|---|
Insulation | FEP – acc. to DIN 47100 1-8 (core-Ø 0,45 mm) |
Outer sheath | PUR |
Stranding | optimised in layers |
Outer diameter: | approx. 4,6 mm |
Dielectric strength | 1000 V AC over orange inner sheath |
Temperature range | fixed laying: -40°C / +150°C flexible application: -40°C / +150°C |
HV measuring cable – 1 x 8 cores
FEP – acc. to DIN 47100 1-8 (core-Ø 0,45 mm)
PUR
optimised in layers
approx. 4,6 mm
1000 V AC over orange inner sheath
fixed laying: -40°C / +150°C
flexible application: -40°C / +150°C
Cable data 2 x 4 cores
Designation | HV measuring cable – 4 x 2 cores |
---|---|
Insulation | FEP – acc. to DIN 47100 1-8 |
Outer sheath | PUR |
Stranding | optimised in layers |
Outer diameter | approx. 7,3 mm |
Dielectric strength | 1000 V AC over orange bundle sheath |
Temperature range | fixed laying: -40°C / +150°C flexible application: -40°C / +150°C |
HV measuring cable – 4 x 2 cores
FEP – acc. to DIN 47100 1-8
PUR
optimised in layers
approx. 7,3 mm
1000 V AC over orange bundle sheath
fixed laying: -40°C / +150°C
flexible application: -40°C / +150°C
Sensor
Type of sensor | 2 x PT100 |
---|---|
Limit deviation | class A |
Wire circuit | 4-wire |
Measuring point | embedded in PI foil adhesive pad |
Dimension of sensor: | for example 2,3 mm x 2,0 mm x 0,47 mm (appropriate for pouch cells) or 3,0 mm x 0,80 mm x 0,60 mm |
Temperature range single channel | -30°C / +180°C |
2 x PT100
class A
4-wire
embedded in PI foil adhesive pad
for example 2,3 mm x 2,0 mm x 0,47 mm (appropriate for pouch cells)
or 3,0 mm x 0,80 mm x 0,60 mm
-30°C / +180°C
Connector
Lemo Redel male connector | with orange kink protection sleeve and black protecting cap, 8-pin, C-coded 1000 V AC voltage-stable – IP 67 when connected |
---|
with orange kink protection sleeve and black protecting cap, 8-pin, C-coded
1000 V AC voltage-stable – IP 67 when connected
Tests
Cable test | core/core – 2500 V AC - 5 min over orange bundle sheath – 5000 V AC – 5 min – with reference to EN 50264-2-1 |
---|---|
Sensor test | Routine test of harnessed connector with reference to standard 61010-1 for measuring devices as well as VDE indications in our in-house ball bath (released by VDE). Control of contact protection towards outside – 3000 V/1 min AC |
core/core – 2500 V AC - 5 min over orange bundle sheath –
5000 V AC – 5 min – with reference to EN 50264-2-1
Routine test of harnessed connector with reference to standard 61010-1 for measuring devices as well as VDE indications in our in-house ball bath (released by VDE).
Control of contact protection towards outside – 3000 V/1 min AC
Configuration examples
item no. | Connection cable length | Length channel 1 | Length channel 2 | |
---|---|---|---|---|
T641-060-817 | 2000 mm | 70 mm | 70 mm | Send inquiry |
T641-060-870 | 5000 mm | 700 mm | 700 mm | Send inquiry |
Total cable and channel lengths can be realised on customer’s request.