Application
LiPFAvn is an PFA insulated stranded hook-up wire with extended temperature range and high resistance against chemicals 375 V. It is recommended for use in high-frequency and broad-band techniques, coaxial and microwave techniques, high information velocity with exact information transmission at the same time, chemical industry, furnace construction, brick works, and heating applicances.
Outstanding features
- excellent resistance against chemicals and solvents
- excellent temperature resistance and flexibility at low temperatures
- excellent electrical insulating characteristics with low, nearly frequency-independent dielectric characteristics
- UL recognized
Additional information
ETFE, FEP, PFA colour code, figures 5 and 6 item-no.:
01 = black | 05 = yellow | 09 = orange |
02 = blue | 06 = green | 11 = red |
03 = brown | 07 = violet | 15 = nature |
04 = grey | 08 = white |
Construction
Conductor | nickel-plated copper strands acc. to ASTM B 286 |
---|---|
Insulation | PFA, 51YI1 acc. to VDE 0207-6 |
nickel-plated copper strands acc. to ASTM B 286
PFA, 51YI1 acc. to VDE 0207-6
Technical data
Peak operating voltage | max. 375 V |
---|---|
Voltage UL | 600 V |
Testing voltage | 2000 V |
Installation | for one single bend the inner bending radius must not be smaller than 0,5 x outer diameter of the insulated strands |
Radiation resistance | 1 x 10⁶ cJ/kg |
Temperature range | fixed laying: -90/+250 °C flexible application: -55/+250 °C limited time of use: +260 °C UL: up to +250 °C |
Fire performance | flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, UL FT2 |
Oil resistance | very good acc. to UL standard 758, at 80 °C after 80 days |
Chem. resistance | very good against acids, halogens, bases, chlorinated solvents as well as organic and inorganic compounds |
Absence of harmful substances | acc. to RoHS directive of the European Union |
max. 375 V
600 V
2000 V
for one single bend the inner bending radius must not be smaller than 0,5 x outer diameter of the insulated strands
1 x 10⁶ cJ/kg
fixed laying: -90/+250 °C
flexible application: -55/+250 °C
limited time of use: +260 °C
UL: up to +250 °C
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, UL FT2
very good acc. to UL standard 758, at 80 °C after 80 days
very good against acids, halogens, bases,
chlorinated solvents as well as organic and
inorganic compounds
acc. to RoHS directive of the European Union
Dimensions
item no. | Dimension |
nominal single wire-ø | Approx. outer-ø | Copper figure | Cable weight ≈ | |
---|---|---|---|---|---|---|
L3344 .. 28* | AWG 28/7 | 0,127 mm | 0,71 mm | 0,9 kg/km | 1,4 kg/km | Send inquiry |
L3344 .. 26* | AWG 26/7 | 0,160 mm | 0,80 mm | 1,4 kg/km | 2,0 kg/km | Send inquiry |
L3344 .. 24* | AWG 24/7 | 0,203 mm | 0,93 mm | 2,2 kg/km | 2,9 kg/km | Send inquiry |
L3344 .. 22* | AWG 22/7 | 0,254 mm | 1,08 mm | 3,4 kg/km | 4,2 kg/km | Send inquiry |
L3344 .. 20* | AWG 20/7 | 0,320 mm | 1,28 mm | 5,4 kg/km | 6,3 kg/km | Send inquiry |
wire-ø
*Colour code figures 5 and 6. ─ ETFE insulated strands on request. ─ Other dimensions and colours are possible on request.