Application
Spreader 722 is a control cable for hoisting cages in crane systems. It is used for carriers, for example, spreaders with high mechanical stress and vertical cage operation.
Outstanding features
- for hoisting cage applications
- high breaking load of supporting unit
- oil resistant
- weather resistant
Construction
Conductor | bare copper strands |
---|---|
Insulation | PVC |
Colour code | black cores with consecutive numbers acc. to EN 50334 + VDE 0293-334 and a green-yellow earth wire |
Suspension unit | Aramid braided with lead, 50 m of the suspended cable are supported by a 5 times safety calculation |
Stranding | cores are twisted to bundles with lead cord in the centre |
Wrapping | overlapping non-woven tape |
Stranding | bundle and lead cords twisted, suspension unit in the centre |
Wrapping | overlapping non-woven tape |
Sheath material | PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
Sheath colour | black (RAL 9005) |
bare copper strands
PVC
black cores with consecutive numbers acc. to EN 50334 + VDE 0293-334 and a green-yellow earth wire
Aramid braided with lead, 50 m of the suspended cable are supported by a 5 times safety calculation
cores are twisted to bundles with lead cord in the centre
overlapping non-woven tape
bundle and lead cords twisted, suspension unit in the centre
overlapping non-woven tape
PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2
black (RAL 9005)
Technical data
Nominal voltage | Uo/U 300/500 V |
---|---|
Testing voltage | core/core 2000 V |
Temperature range | fixed laying: -20/+60°C flexible application: -20/+60°C max. allowed operating temperature at conductor: +70°C short circuit temperature at conductor: +150°C |
Tensile strength | max. 15 N/mm² x sum of all cable sections |
Recommended cage dimensions | cage diameter min. 30 x d, cage height approx. 45 x d |
Travel speed hoisting gear | max. 160 m/min. |
Oil resistance | very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
Weather resistance | appropiate for applications in dry, damp and wet rooms as well as in the open-air with a very good resistance against ozone, UV radiation and humidity
Due to the Iead cord this cable isn’t free of harmful substances acc. to RoHS directive of the European Union |
Uo/U 300/500 V
core/core 2000 V
fixed laying: -20/+60°C
flexible application: -20/+60°C
max. allowed operating temperature at conductor: +70°C
short circuit temperature at conductor: +150°C
max. 15 N/mm² x sum of all cable sections
cage diameter min. 30 x d,
cage height approx. 45 x d
max. 160 m/min.
very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2
appropiate for applications in dry, damp and wet rooms as well as in the open-air with a very good resistance against ozone, UV radiation and humidity
Due to the Iead cord this cable isn’t free of harmful substances acc. to RoHS directive of the European Union
Dimensions
item no. |
No. of cores x cross section | Outer-ø ± 10% | Copper figure | Cable weight ≈ | |
---|---|---|---|---|---|
L07224810 | 48 G 1,00 mm² | 32,1 mm | 460,8 kg/km | 1951 kg/km | Send inquiry |
L07222425 | 24 G 2,50 mm² | 29,7 mm | 576 kg/km | 1660 kg/km | Send inquiry |
L07223025 | 30 G 2,50 mm² | 32,9 mm | 720 kg/km | 2016 kg/km | Send inquiry |
L07223625 | 36 G 2,50 mm² | 36,2 mm | 864 kg/km | 2567 kg/km | Send inquiry |
L07224225 | 42 G 2,50 mm² | 39,2 mm | 1008 kg/km | 3177 kg/km | Send inquiry |
L07224825 | 48 G 2,50 mm² | 41,9 mm | 1152 kg/km | 3556 kg/km | Send inquiry |
L07222035 | 20 G 3,50 mm² | 30,9 mm | 633,6 kg/km | 1722 kg/km | Send inquiry |
L07222435 | 24 G 3,50 mm² | 33,2 mm | 760,3 kg/km | 2073 kg/km | Send inquiry |
L07223035 | 30 G 3,50 mm² | 37 mm | 950,4 kg/km | 2565 kg/km | Send inquiry |
L07223635 | 36 G 3,50 mm² | 40,2 mm | 1140,5 kg/km | 3218 kg/km | Send inquiry |