Application
This silicone insulated cable has a PETP foil wrapping with bare copper earth wire 0,5 mm ∅. The conductor cross section is 1,5 mm² and the outer diameter is approx. 7,0 mm. It is available as compensating and extension cable.
Additional information
With alu foil screen!
DIN 43710 / 43714 (not valid for type B*)
* Not standardized compensating cable for thermocouples type B with application temperatures up to 100 °C resp. 200 °C.
C = compensating cables · X = extension cables
Construction
Insulation | Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1 |
---|---|
Stranding | 2 cores together |
Wrapping | PETP foil, with bare copper earth wire 0,5 mm Ø |
Screen | Alu-foil |
Sheath material | Besilen® EM9 acc. to EN 50363-2-1 + VDE 0207-363-2-1 |
Shape | round |
Conductor construction | strand |
Conductor cross section | A 6 L: 1,5 mm² A 6-022 L: 0,22 mm² |
Outer diameter | A 6 L: approx. 7,0 mm A 6-022 L: approx. 4,4 mm |
Weight/100m | A 6 L: approx. 6,1 kg A 6-022 L: approx. 2,0 kg |
Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1
2 cores together
PETP foil,
with bare copper earth wire 0,5 mm Ø
Alu-foil
Besilen® EM9 acc. to EN 50363-2-1 + VDE 0207-363-2-1
round
strand
A 6 L: 1,5 mm²
A 6-022 L: 0,22 mm²
A 6 L: approx. 7,0 mm
A 6-022 L: approx. 4,4 mm
A 6 L: approx. 6,1 kg
A 6-022 L: approx. 2,0 kg
Technical data
Min. bending radius | 7,5 x d |
---|---|
Radiation resistance | 2 x 10^7 cJ/kg |
Temperature range | fixed laying: -40/+180°C flexible application: -25/+180°C short-time use: +250°C |
Insulation resistance | > 1 M Ω x km |
Halogen-free | acc. to IEC 60754-1 + VDE 0482-754-1 |
Fire performance | flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 |
Corrosiveness of conflagration gases | in compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases |
Absence of harmful substances | acc. to RoHS directive of the European Union |
7,5 x d
2 x 10^7 cJ/kg
fixed laying: -40/+180°C
flexible application: -25/+180°C
short-time use: +250°C
> 1 M Ω x km
acc. to IEC 60754-1 + VDE 0482-754-1
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2
in compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases
acc. to RoHS directive of the European Union
Dimensions
item no. | Type | Colour code | For thermocouple |
Thermocouple material +Pol/-Pol | Cable type |
Colour code core insulation +Pol/-Pol (Sheath) | EMF at 100 °C | |
---|---|---|---|---|---|---|---|---|
L04288958 | A 6 L | IEC 60584 | Type T | Cu - CuNi | TX | brown/white (brown) | 4,28 mV | Send inquiry |
L04288952 | A 6 L | IEC 60584 | Type J | Fe - CuNi | JX | black/white (black) | 5,27 mV | Send inquiry |
L04288995 | A 6 L | IEC 60584 | Type K | NiCr - Ni | KCA | green/white (green) | 4,10 mV | Send inquiry |
L04288999 | A 6 L | IEC 60584 | Type K | NiCr - Ni | KCB | green/white (green) | 4,10 mV | Send inquiry |
L04288954 | A 6 L | IEC 60584 | Type K | NiCr - Ni | KX | green/white (green) | 4,10 mV | Send inquiry |
L04288953 | A 6 L | IEC 60584 | Type E | NiCr - CuNi | EX | violet/white (violet) | 6,32 mV | Send inquiry |
L04288997 | A 6 L | IEC 60584 | Type R/S | PtRh13 - PTPtRh10 - PT | R/SCB | orange/white (orange) | 0,65 mV | Send inquiry |
L04288991 | A 6 L | IEC 60584 | Type N | NiCrSi - NiSi | NC | pink/white (pink) | 2,77 mV | Send inquiry |
L04288992 | A 6 L | DIN 43710 / 43714 | Type L | Fe CuNi | LX | red/blue (blue) | 5,37 mV | Send inquiry |
L04288994 | A 6 L | DIN 43710 / 43714 | Type K | ─ | KCA | ─ | 4,10 mV | Send inquiry |
L04288996 | A 6 L | DIN 43710 / 43714 | Type R/S | ─ | R/SCB | ─ | 0,65 mV | Send inquiry |
L04288998 | A 6 L | DIN 43710 / 43714 | Type U | Cu - CuNi | UX | red/brown (brown) | 4,25 mV | Send inquiry |
L04288901 | A 6 L | DIN 43710 / 43714 | Type B* | ─ | BC-100 | ─ | 0,00 mV | Send inquiry |
L04288902 | A 6 L | DIN 43710 / 43714 | Type B* | ─ | BC-200 | ─ | 0,033 mV | Send inquiry |
L04285958 | A 6-022 L | IEC 60584 | Type T | Cu - CuNi | TX | brown/white (brown) | 4,28 mV | Send inquiry |
L04285952 | A 6-022 L | IEC 60584 | Type J | Fe - CuNi | JX | black/white (black) | 5,27 mV | Send inquiry |
L04285995 | A 6-022 L | IEC 60584 | Type K | NiCr - Ni | KCA | green/white (green) | 4,10 mV | Send inquiry |
L04285999 | A 6-022 L | IEC 60584 | Type K | NiCr - Ni | KCB | green/white (green) | 4,10 mV | Send inquiry |
L04285954 | A 6-022 L | IEC 60584 | Type K | NiCr - Ni | KX | green/white (green) | 4,10 mV | Send inquiry |
L04285953 | A 6-022 L | IEC 60584 | Type E | NiCr - CuNi | EX | violet/white (violet) | 6,32 mV | Send inquiry |
L04285997 | A 6-022 L | IEC 60584 | Type R/S | PtRh13 - PTPtRh10 - PT | R/SCB | orange/white (orange) | 0,65 mV | Send inquiry |
L04285991 | A 6-022 L | IEC 60584 | Type N | NiCrSi - NiSi | NC | pink/white (pink) | 2,77 mV | Send inquiry |
L04285992 | A 6-022 L | DIN 43710 / 43714 | Type L | Fe CuNi | LX | red/blue (blue) | 5,37 mV | Send inquiry |
L04285994 | A 6-022 L | DIN 43710 / 43714 | Type K | ─ | KCA | ─ | 4,10 mV | Send inquiry |
L04285996 | A 6-022 L | DIN 43710 / 43714 | Type R/S | ─ | R/SCB | ─ | 0,65 mV | Send inquiry |
L04285998 | A 6-022 L | DIN 43710 / 43714 | Type U | Cu - CuNi | UX | red/brown (brown) | 4,25 mV | Send inquiry |
L04285901 | A 6-022 L | DIN 43710 / 43714 | Type B* | ─ | BC-100 | ─ | 0,00 mV | Send inquiry |
L04285902 | A 6-022 L | DIN 43710 / 43714 | Type B* | ─ | BC-200 | ─ | 0,033 mV | Send inquiry |
material +Pol/-Pol
core insulation
+Pol/-Pol (Sheath)
We continue to manufacture compensating and extension cables with colour code acc. to DIN 43714 and the basic values of DIN 43710.