Application
Type J Thermocouple Wire, silicone insulated with insulated strands has a steel wire armouring and a fibre-glass braiding. This Thermocouple Wire is available for thermocouples Type J, Type K, Type L, Type S, Type R/S.
Additional information
DIN 43710 / 43714 (not valid for type B*)
* Not standardized compensating cable for thermocouples type B with application temperatures up to 100 °C resp. 200 °C.
C = compensating cables · X = extension cables
Also available with cross-sections 1,0 mm², 0,75 mm², 0,5 mm² and 0,22 mm²!
Construction
Insulation | Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1 |
---|---|
Stranding | 2 resp. 4 cores together |
Braiding | fibre-glass |
Armouring | galvanized steel wire armouring with tracer |
Shape | round |
Conductor construction | wire |
Conductor cross section | 1,5 mm² |
Outer diameter | approx. 5,5 mm |
Weight/100m | approx. 6,4 kg |
Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1
2 resp. 4 cores together
fibre-glass
galvanized steel wire armouring with tracer
round
wire
1,5 mm²
approx. 5,5 mm
approx. 6,4 kg
Technical data
Min. bending radius | 12 x d |
---|---|
Temperature range of insulation | fixed laying: -40/+180°C flexible application: -25/+180°C short-time use: +250°C |
Insulation resistance | > 1 M Ω x km |
Halogen-free | acc. to IEC 60754-1 + VDE 0482-754-1 |
Fire performance | flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 |
Corrosiveness of conflagration gases | in compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases |
Absence of harmful substances | acc. to RoHS directive of the European Union |
12 x d
fixed laying: -40/+180°C
flexible application: -25/+180°C
short-time use: +250°C
> 1 M Ω x km
acc. to IEC 60754-1 + VDE 0482-754-1
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2
in compliance with IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases
acc. to RoHS directive of the European Union
Dimensions
item no. | Colour code | For thermocouple |
Thermocouple material +Pol/-Pol | Cable type |
Colour code core insulation +Pol/-Pol (Sheath) | EMF at 100 °C | |
---|---|---|---|---|---|---|---|
L04238988 | IEC 60584 | Type T | Cu - CuNi | TX | brown/white (brown) | 4,28 mV | Send inquiry |
L04238982 | IEC 60584 | Type J | Fe - CuNi | JX | black/white (black) | 5,27 mV | Send inquiry |
L04238915 | IEC 60584 | Type K | NiCr - Ni | KCA | green/white (green) | 4,10 mV | Send inquiry |
L04238919 | IEC 60584 | Type K | NiCr - Ni | KCB | green/white (green) | 4,10 mV | Send inquiry |
L04238984 | IEC 60584 | Type K | NiCr - Ni | KX | green/white (green) | 4,10 mV | Send inquiry |
L04238983 | IEC 60584 | Type E | NiCr - CuNi | EX | purple/white (purple) | 6,32 mV | Send inquiry |
L04238917 | IEC 60584 | Type R/S | PtRh13 - PTPtRh10 - PT | R/SCB | orange/white (orange) | 0,65 mV | Send inquiry |
L04238911 | IEC 60584 | Type N | NiCrSi - NiSi | NC | pink/white (pink) | 2,77 mV | Send inquiry |
L04238912 | DIN 43710 / 43714 | Type L | Fe CuNi | LX | red/blue (blue) | 5,37 mV | Send inquiry |
L04238914 | DIN 43710 / 43715 | Type K | ─ | KCA | ─ | 4,10 mV | Send inquiry |
L04238916 | DIN 43710 / 43716 | Type R/S | ─ | R/SCB | ─ | 0,65 mV | Send inquiry |
L04238918 | DIN 43710 / 43717 | Type U | Cu - CuNi | UX | red/brown (brown) | 4,25 mV | Send inquiry |
L04238921 | DIN 43710 / 43718 | Type B* | ─ | BC-100 | ─ | 0,00 mV | Send inquiry |
L04238922 | DIN 43710 / 43719 | Type B* | ─ | BC200 | ─ | 0,033 mV | Send inquiry |
material +Pol/-Pol
core insulation
+Pol/-Pol (Sheath)
We continue to manufacture compensating and extension cables with colour code acc. to DIN 43714 and the basic values of DIN 43710.