LiPFAvn (375 V)

PFA insulated stranded hook-up wire with extended temperature range, 375 V

Application

LiPFAvn is an PFA insulated stranded hook-up wire with extended temperature range and high resistance against chemicals 375 V. It is recommended for use in high-frequency and broad-band techniques, coaxial and microwave techniques, high information velocity with exact information transmission at the same time, chemical industry, furnace construction, brick works, and heating applicances.

Outstanding features

  • excellent resistance against chemicals and solvents
  • excellent temperature resistance and flexibility at low temperatures
  • excellent electrical insulating characteristics with low, nearly frequency-independent dielectric characteristics
  • UL recognized

Additional information

ETFE, FEP, PFA colour code, figures 5 and 6 item-no.:

 

01 = black05 = yellow09 = orange
02 = blue06 = green11 = red
03 = brown07 = violet15 = nature
04 = grey08 = white 

 

Construction

Conductor

nickel-plated copper strands acc. to ASTM B 286

Insulation

PFA, 51YI1 acc. to VDE 0207-6

Conductor

nickel-plated copper strands acc. to ASTM B 286

Insulation

PFA, 51YI1 acc. to VDE 0207-6

Technical data

Peak operating voltage

max. 375 V

Voltage UL

600 V

Testing voltage

2000 V

Installation

for one single bend the inner bending radius must not be smaller than 0,5 x outer diameter of the insulated strands

Radiation resistance

1 x 10⁶ cJ/kg

Temperature range

fixed laying: -90/+250 °C

flexible application: -55/+250 °C

limited time of use: +260 °C

UL: up to +250 °C

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, UL FT2

Oil resistance

very good acc. to UL standard 758, at 80 °C after 80 days

Chem. resistance

very good against acids, halogens, bases,

chlorinated solvents as well as organic and

inorganic compounds

Absence of harmful substances

acc. to RoHS directive of the European Union

Peak operating voltage

max. 375 V

Voltage UL

600 V

Testing voltage

2000 V

Installation

for one single bend the inner bending radius must not be smaller than 0,5 x outer diameter of the insulated strands

Radiation resistance

1 x 10⁶ cJ/kg

Temperature range

fixed laying: -90/+250 °C

flexible application: -55/+250 °C

limited time of use: +260 °C

UL: up to +250 °C

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, UL FT2

Oil resistance

very good acc. to UL standard 758, at 80 °C after 80 days

Chem. resistance

very good against acids, halogens, bases,

chlorinated solvents as well as organic and

inorganic compounds

Absence of harmful substances

acc. to RoHS directive of the European Union

Dimensions

item no. Dimension nominal single
wire-ø
Approx. outer-ø Copper figure Cable weight ≈
L3344 .. 28*AWG 28/70,127 mm0,71 mm0,9 kg/km1,4 kg/km Send inquiry
L3344 .. 26*AWG 26/70,160 mm0,80 mm1,4 kg/km2,0 kg/km Send inquiry
L3344 .. 24*AWG 24/70,203 mm0,93 mm2,2 kg/km2,9 kg/km Send inquiry
L3344 .. 22*AWG 22/70,254 mm1,08 mm3,4 kg/km4,2 kg/km Send inquiry
L3344 .. 20*AWG 20/70,320 mm1,28 mm5,4 kg/km6,3 kg/km Send inquiry
item no.
Dimension
nominal single
wire-ø
Approx. outer-ø
Copper figure
Cable weight ≈
L3344 .. 28*
AWG 28/7
0,127 mm
0,71 mm
0,9 kg/km
1,4 kg/km
L3344 .. 26*
AWG 26/7
0,160 mm
0,80 mm
1,4 kg/km
2,0 kg/km
L3344 .. 24*
AWG 24/7
0,203 mm
0,93 mm
2,2 kg/km
2,9 kg/km
L3344 .. 22*
AWG 22/7
0,254 mm
1,08 mm
3,4 kg/km
4,2 kg/km
L3344 .. 20*
AWG 20/7
0,320 mm
1,28 mm
5,4 kg/km
6,3 kg/km

*Colour code figures 5 and 6. ─ ETFE insulated strands on request. ─ Other dimensions and colours are possible on request.

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00