CC 600 CY T (AWG 20 - AWG 10)
PVC control cable with numbered cores, extended temperature range and overall copper screen acc. to UL/CSA
Application
CC 600 CY T is an approved PVC control cable with extended temperature range, overall copper screen, and numbered cores as well as AWG 20 - AWG 10. It is recommended for use in machine tool and packaging machine construction, material handling and automation technologies, car manufacturing industry, CNC-machines.
Outstanding features
- UL and CSA approved
- Temperature range up to + 105°C
Construction
Conductor | bare copper strands acc. to IEC 60228, VDE 0295, class 5 |
---|---|
Insulation | special heat resistant PVC |
Colour code | black cores with consecutive numbers acc. to EN 50334 + VDE 0293-334, green-yellow earth wire from 3 cores |
Stranding | in layers with PETP foil over the outer layer |
Screen | tinned copper braiding |
Sheath material | special heat resistant PVC |
Sheath colour | grey (RAL 7000) |
bare copper strands acc. to IEC 60228, VDE 0295, class 5
special heat resistant PVC
black cores with consecutive numbers acc. to EN 50334 + VDE 0293-334,
green-yellow earth wire from 3 cores
in layers
with PETP foil over the outer layer
tinned copper braiding
special heat resistant PVC
grey (RAL 7000)
Technical data
Nominal voltage | DIN VDE: Uo/U 300/500 V UL/CSA: 600 V |
---|---|
Testing voltage | core/core 2000 V core/screen 2000 V |
Min. bending radius | fixed laying: 5 x d flexible application: 10 x d |
Radiation resistance | 8 x 10^7 cJ/kg |
Temperature range | DIN VDE fixed laying: -40/+90 °C DIN VDE flexible application: +5/+90 °C DIN VDE short-time use: +105 °C UL/CSA fixed laying: up to +105 °C UL/CSA flexible application: up to +105 °C |
Fire performance | flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, |
Oil resistance | |
Absence of harmful substances | acc. to RoHS directive of the European Union |
DIN VDE: Uo/U 300/500 V
UL/CSA: 600 V
core/core 2000 V
core/screen 2000 V
fixed laying: 5 x d
flexible application: 10 x d
8 x 10^7 cJ/kg
DIN VDE fixed laying: -40/+90 °C
DIN VDE flexible application: +5/+90 °C
DIN VDE short-time use: +105 °C
UL/CSA fixed laying: up to +105 °C
UL/CSA flexible application: up to +105 °C
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2,
UL VW-1, CSA FT1, FT2
acc. to RoHS directive of the European Union
Dimensions
item no. |
No. of cores x cross section |
Largest single wire-ø | Copper figure | Cable weight ≈ | Outer-ø ± 5% | |
---|---|---|---|---|---|---|
L02782002 | 2 x 20 AWG | 0,21 mm | 26 kg/km | 46 kg/km | 5,8 mm | Send inquiry |
L02782003 | 3 x 20 AWG | 0,21 mm | 31,5 kg/km | 56 kg/km | 6,2 mm | Send inquiry |
L02782004 | 4 x 20 AWG | 0,21 mm | 48,7 kg/km | 66 kg/km | 6,6 mm | Send inquiry |
L02782007 | 7 x 20 AWG | 0,21 mm | 68,2 kg/km | 100 kg/km | 7,9 mm | Send inquiry |
L02782012 | 12 x 20 AWG | 0,21 mm | 111,5 kg/km | 175 kg/km | 10,6 mm | Send inquiry |
L02782015 | 15 x 20 AWG | 0,21 mm | 128,1 kg/km | 210 kg/km | 11,6 mm | Send inquiry |
L02782025 | 25 x 20 AWG | 0,21 mm | 196,7 kg/km | 320 kg/km | 14,6 mm | Send inquiry |
L02781802 | 2 x 18 AWG | 0,21 mm | 47,4 kg/km | 60 kg/km | 6,6 mm | Send inquiry |
L02781803 | 3 x 18 AWG | 0,21 mm | 57,6 kg/km | 75 kg/km | 6,9 mm | Send inquiry |
L02781804 | 4 x 18 AWG | 0,21 mm | 70,3 kg/km | 93 kg/km | 7,7 mm | Send inquiry |
L02781805 | 5 x 18 AWG | 0,21 mm | 85,6 kg/km | 111 kg/km | 8,3 mm | Send inquiry |
L02781807 | 7 x 18 AWG | 0,21 mm | 105,6 kg/km | 143 kg/km | 9,2 mm | Send inquiry |
L02781812 | 12 x 18 AWG | 0,21 mm | 166,9 kg/km | 245 kg/km | 12,2 mm | Send inquiry |
L02781815 | 15 x 18 AWG | 0,21 mm | 205,2 kg/km | 304 kg/km | 13,6 mm | Send inquiry |
L02781818 | 18 x 18 AWG | 0,21 mm | 240,8 kg/km | 343 kg/km | 14,3 mm | Send inquiry |
L02781825 | 25 x 18 AWG | 0,21 mm | 343,7 kg/km | 483 kg/km | 17,3 mm | Send inquiry |
L02781850 | 50 x 18 AWG | 0,21 mm | 620,3 kg/km | 902 kg/km | 23,3 mm | Send inquiry |
L02781602 | 2 x 16 AWG | 0,26 mm | 58,3 kg/km | 74 kg/km | 7,2 mm | Send inquiry |
L02781603 | 3 x 16 AWG | 0,26 mm | 75,3 kg/km | 95 kg/km | 7,8 mm | Send inquiry |
L02781604 | 4 x 16 AWG | 0,26 mm | 95,3 kg/km | 116 kg/km | 8,4 mm | Send inquiry |
L02781605 | 5 x 16 AWG | 0,26 mm | 110,5 kg/km | 144 kg/km | 9,3 mm | Send inquiry |
L02781607 | 7 x 16 AWG | 0,26 mm | 150,7 kg/km | 193 kg/km | 10,3 mm | Send inquiry |
L02781612 | 12 x 16 AWG | 0,26 mm | 231,2 kg/km | 319 kg/km | 13,7 mm | Send inquiry |
L02781615 | 15 x 16 AWG | 0,26 mm | 285,3 kg/km | 393 kg/km | 15,2 mm | Send inquiry |
L02781618 | 18 x 16 AWG | 0,26 mm | 358,2 kg/km | 475 kg/km | 16,4 mm | Send inquiry |
L02781625 | 25 x 16 AWG | 0,26 mm | 476,2 kg/km | 642 kg/km | 19,6 mm | Send inquiry |
L02781650 | 50 x 16 AWG | 0,26 mm | 881 kg/km | 1179 kg/km | 25,8 mm | Send inquiry |
L02781403 | 3 x 14 AWG | 0,26 mm | 110,5 kg/km | 139 kg/km | 9,3 mm | Send inquiry |
L02781404 | 4 x 14 AWG | 0,26 mm | 145,8 kg/km | 184 kg/km | 10,2 mm | Send inquiry |
L02781405 | 5 x 14 AWG | 0,26 mm | 171,8 kg/km | 227 kg/km | 11,4 mm | Send inquiry |
L02781407 | 7 x 14 AWG | 0,26 mm | 222,2 kg/km | 289 kg/km | 12,5 mm | Send inquiry |
L02781412 | 12 x 14 AWG | 0,26 mm | 388 kg/km | 498 kg/km | 16,8 mm | Send inquiry |
L02781418 | 18 x 14 AWG | 0,26 mm | 548,8 kg/km | 709 kg/km | 19,8 mm | Send inquiry |
L02781425 | 25 x 14 AWG | 0,26 mm | 754 kg/km | 979 kg/km | 23,9 mm | Send inquiry |
L02781203 | 3 x 12 AWG | 0,31 mm | 165,8 kg/km | 205 kg/km | 10,9 mm | Send inquiry |
L02781204 | 4 x 12 AWG | 0,31 mm | 206,1 kg/km | 264 kg/km | 12,1 mm | Send inquiry |
L02781205 | 5 x 12 AWG | 0,31 mm | 252,9 kg/km | 320 kg/km | 13,2 mm | Send inquiry |
L02781207 | 7 x 12 AWG | 0,31 mm | 337,7 kg/km | 433 kg/km | 15 mm | Send inquiry |
L02781003 | 3 x 10 AWG | 0,31 mm | 232,8 kg/km | 291 kg/km | 12,7 mm | Send inquiry |
L02781004 | 4 x 10 AWG | 0,31 mm | 298 kg/km | 365 kg/km | 13,9 mm | Send inquiry |
L02781005 | 5 x 10 AWG | 0,31 mm | 358,1 kg/km | 450 kg/km | 15,4 mm | Send inquiry |
cross section
wire-ø
Other dimensions and colours are possible on request.