SABclean CATLine CAT 6A S

Industrial Ethernet CAT 6A Cable, suitable for cable tracks

Marking for SABClean CATLine CAT 6A S:
SAB BRÖCKSKES · D-VIERSEN · SABClean Cat.6A S 4x2x26AWG 1677-9006 UL AWM Style 20549 80°C 300V CE RoHS and current meter marking

Marking for SABClean CATLine CAT 6A S: SAB BRÖCKSKES · D-VIERSEN · SABClean Cat.6A S 4x2x26AWG 1677-9006 UL AWM Style 20549 80°C 300V CE RoHS and current meter marking

Application

Industrial Ethernet cable CAT 6A suitable for drag chains for use in clean room applications. This highly flexible drag chain cable with UL AWM Style 20549 80°C can be used for temperatures up to +80 °C. In addition to the good flexibility, the CAT 6A cable is oil-resistant (Oil 60 °C according to UL 758).

Additional information

Cleanroom classification
DIN EN ISO 14644-1 air cleanliness class 1

 

Also possible as harnessed cable with M12 or RJ 45 plug!

Construction

Dimension

4 x 2 x 26 AWG

Conductor

bare copper strands, fine wire

Insulation

special polymer

Colour code

white-blue/blue, white-orange/orange, white-green/green, white-brown/brown

Stranding

cores twisted to pairs, pairs together

Screen

alu foil and tinned copper braiding

Wrapping

non-woven tape

Sheath material

TPE

Sheath colour

black (RAL 9005)

Dimension

4 x 2 x 26 AWG

Conductor

bare copper strands, fine wire

Insulation

special polymer

Colour code

white-blue/blue, white-orange/orange, white-green/green, white-brown/brown

Stranding

cores twisted to pairs, pairs together

Screen

alu foil and tinned copper braiding

Wrapping

non-woven tape

Sheath material

TPE

Sheath colour

black (RAL 9005)

Technical data

Item number

1677-9006

Peak operating voltage

max. 90 V

Voltage UL

300 V

Testing voltage

core/core 2000 V

core/screen 2000 V

Min. bending radius

fixed laying: 5 x d

flexible application: 10 x d

continuously flexible: 15 x d

Temperature range

UL: up to +80 °C

fixed laying: -40/+70 °C

flexible application: -30/+70 °C

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Flame test

UL Horizontal Flame Test FT2

Characteristic impedance

100Ω ± 10Ω,

fulfils the electrical and transmission requirements with high frequency with reference to EN 50288-10-2 / CAT 6A

Oil resistance

very good - Oil 60 °C acc. to UL 758

Flexibility

very good

Air cleanliness class 1

acc. to DIN EN ISO 14644-1

UL Style

20549

Absence of harmful substances

acc. to RoHS directive of the European Union

Item number

1677-9006

Peak operating voltage

max. 90 V

Voltage UL

300 V

Testing voltage

core/core 2000 V

core/screen 2000 V

Min. bending radius

fixed laying: 5 x d

flexible application: 10 x d

continuously flexible: 15 x d

Temperature range

UL: up to +80 °C

fixed laying: -40/+70 °C

flexible application: -30/+70 °C

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Flame test

UL Horizontal Flame Test FT2

Characteristic impedance

100Ω ± 10Ω,

fulfils the electrical and transmission requirements with high frequency with reference to EN 50288-10-2 / CAT 6A

Oil resistance

very good - Oil 60 °C acc. to UL 758

Flexibility

very good

Air cleanliness class 1

acc. to DIN EN ISO 14644-1

UL Style

20549

Absence of harmful substances

acc. to RoHS directive of the European Union

Dimensions

item no. Dimension max. outer-ø Copper figure Cable weight ≈
L167790064 x 2 x 26 AWG6,9 mm31,8 kg/km56 kg/km Send inquiry
item no.
Dimension
max. outer-ø
Copper figure
Cable weight ≈
L16779006
4 x 2 x 26 AWG
6,9 mm
31,8 kg/km
56 kg/km

Other dimensions and colours are possible on request.

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00