BiL

Silicone (Besilen®) insulated single conductor for tube lamps (neon cable)

Application

BiL is a silicone insulated single conductor for tube lamps. Moreover, it is neon coloured. Single conductors for tube lamps are used at high and very unsteady ambient temperatures, mostly in lamp and illumination industries, e.g. for floodlight projectors or industrial lamps, drop lights, and equipment lights (protected installation is necessary). 

Outstanding features

  • halogen-free
  • flexible at low temperatures
  • heat resistant
  • neon coloured

Construction

Conductor

tinned copper strands

acc. to IEC 60228, VDE 0295, class 5

Insulation

Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1

Sheath colour

yellow (similar RAL 1006)

Conductor

tinned copper strands

acc. to IEC 60228, VDE 0295, class 5

Insulation

Besilen® EI2 acc. to EN 50363-1 + VDE 0207-363-1

Sheath colour

yellow (similar RAL 1006)

Technical data

Nominal voltage

Uo 3,5 kV / Uo 4,0 kV / Uo 7,5 kV

Testing voltage

10 kV

Min. bending radius

7,5 x d

Radiation resistance

2 x 10^7 cJ/kg

Temperature range

fixed laying: -40/+180°C

flexible application: -25/+180°C

short-time use: +250°C

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Corrosiveness of conflagration gases

IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases

Chem. resistance

see "Technical Data" - Chemical resistance

Weather resistance

very good

Absence of harmful substances

acc. to RoHS directive of the European Union

Nominal voltage

Uo 3,5 kV / Uo 4,0 kV / Uo 7,5 kV

Testing voltage

10 kV

Min. bending radius

7,5 x d

Radiation resistance

2 x 10^7 cJ/kg

Temperature range

fixed laying: -40/+180°C

flexible application: -25/+180°C

short-time use: +250°C

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2

Corrosiveness of conflagration gases

IEC 60754-2 + VDE 0482-754-2 - no development of corrosive conflagration gases

Chem. resistance

see "Technical Data" - Chemical resistance

Weather resistance

very good

Absence of harmful substances

acc. to RoHS directive of the European Union

Dimensions

item no. Nominal cross
section
Largest single
wire-ø
Nominal voltage Copper figure Cable weight ≈ Outer-ø ± 5%
L010635151,5 mm²0,26 mm3,5 kV14,4 kg/km32 kg/km4,4 mm Send inquiry
L010648151,5 mm²0,26 mm4 kV14,4 kg/km59 kg/km6,6 mm Send inquiry
L010675151,5 mm²0,26 mm7,5 kV14,4 kg/km75 kg/km7,6 mm Send inquiry
item no.
Nominal cross
section
Largest single
wire-ø
Nominal voltage
Copper figure
Cable weight ≈
Outer-ø ± 5%
L01063515
1,5 mm²
0,26 mm
3,5 kV
14,4 kg/km
32 kg/km
4,4 mm
L01064815
1,5 mm²
0,26 mm
4 kV
14,4 kg/km
59 kg/km
6,6 mm
L01067515
1,5 mm²
0,26 mm
7,5 kV
14,4 kg/km
75 kg/km
7,6 mm

Other dimensions and colours are possible on request.

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00