Application
ETFE insulated stranded hook-up wire with extended temperature range and good electrical insulating characteristics. The cold-flexible ETFE cable is recommended for use in high-frequency and broad-band techniques, coaxial and microwave techniques, high information velocity with exact information transmission at the same time, chemical industry, furnace construction, brick works, and heating appliances.
Outstanding features
- high resistance against chemicals and solvents
- low and high temperature resistance
- good electrical insulating characteristics with low, nearly frequency-independent dielectric characteristics
Additional information
ETFE, FEP, PFA colour code, figures 5 and 6 item-no.:
01 = black | 05 = yellow | 09 = orange |
02 = blue | 06 = green | 11 = red |
03 = brown | 07 = violet | 15 = nature |
04 = grey | 08 = white |
Construction
Conductor | bare copper strands acc. to ASTM B 286 |
---|---|
Insulation | ETFE, 7YI1 acc. to VDE 0207-6 |
bare copper strands acc. to ASTM B 286
ETFE, 7YI1 acc. to VDE 0207-6
Technical data
Peak operating voltage | max. 900 V |
---|---|
Testing voltage | 2500 V |
Installation | for one single bend the inner bending radius must not be smaller than 0,5 x outer diameter of the insulated wire |
Radiation resistance | 2 x 10⁸ cJ/kg |
Temperature range | fixed laying: -90/+135°C flexible application: -55/+135°C limited time of use: +150°C |
Fire performance | flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 |
Chem. resistance | very good against acids, halogens, bases, chlorinated solvents as well as organic and inorganic compounds |
Absence of harmful substances | acc. to RoHS directive of the European Union |
max. 900 V
2500 V
for one single bend the inner bending radius must not be smaller than 0,5 x outer diameter of the insulated wire
2 x 10⁸ cJ/kg
fixed laying: -90/+135°C
flexible application: -55/+135°C
limited time of use: +150°C
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2
very good against acids, halogens, bases, chlorinated solvents as well as organic and inorganic compounds
acc. to RoHS directive of the European Union
Dimensions
item no. | Dimension |
nominal single wire-ø | max. outer-ø | Copper figure | Cable weight ≈ | |
---|---|---|---|---|---|---|
L3345 .. 28* | AWG 28/7 | 0,127 mm | 0,93 mm | 0,9 kg/km | 1,8 kg/km | Send inquiry |
L3345 .. 26* | AWG 26/7 | 0,160 mm | 1,03 mm | 1,3 kg/km | 2,4 kg/km | Send inquiry |
L3345 .. 24* | AWG 24/7 | 0,203 mm | 1,16 mm | 2,2 kg/km | 3,4 kg/km | Send inquiry |
L3345 .. 22* | AWG 22/7 | 0,254 mm | 1,31 mm | 3,5 kg/km | 4,8 kg/km | Send inquiry |
L3345 .. 20* | AWG 20/7 | 0,320 mm | 1,51 mm | 5,4 kg/km | 7,0 kg/km | Send inquiry |
L3345 .. 18* | AWG 18/19 | 0,254 mm | 1,78 mm | 9,2 kg/km | 11,0 kg/km | Send inquiry |
L3345 .. 16* | AWG 16/19 | 0,287 mm | 1,94 mm | 11,8 kg/km | 14,0 kg/km | Send inquiry |
L3345 .. 14* | AWG 14/19 | 0,361 mm | 2,30 mm | 18,7 kg/km | 21,0 kg/km | Send inquiry |
L3345 .. 12* | AWG 12/19 | 0,455 mm | 2,76 mm | 29,7 kg/km | 32,0 kg/km | Send inquiry |
wire-ø