Application
DR 717 P Highflex is a highflex reeling cable 300/500 V. This reeling cable is used for spring cable reels on stages and theatres.
Outstanding features
- reeling length up to 60 m
- extrem highly winding and unwinding strength
- corresponds to low voltage guideline 73/23/EWG CE
- small outer diameter
- small cable weight
Construction
Conductor | bare copper strands acc. to IEC 60228, VDE 0295, class 5 |
---|---|
Insulation | special polymer |
Colour code | coloured acc. to HD 308 (VDE 0293-308) from 6 cores black cores, with consecutive numbers acc. to EN 50334 + VDE 0293-334, from 3 cores a green-yellow earth wire, DMX-bus: white/brown, green/yellow, IE Cat 5:white-blue/blue, white-orange/orange, white-green/green, white-brown/brown |
Stranding | specially adjusted layering around central suspension unit |
Inner sheath | PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
Supporting screen | high-tech yarn |
Sheath material | PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
Sheath colour | black (RAL 9005) |
bare copper strands acc. to IEC 60228, VDE 0295, class 5
special polymer
coloured acc. to HD 308 (VDE 0293-308) from 6 cores black cores, with consecutive numbers acc. to EN 50334 + VDE 0293-334, from 3 cores a green-yellow earth wire, DMX-bus: white/brown, green/yellow, IE Cat 5:white-blue/blue, white-orange/orange, white-green/green, white-brown/brown
specially adjusted layering around central suspension unit
PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2
high-tech yarn
PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2
black (RAL 9005)
Technical data
Peak operating voltage | item no. 0717-9001: max. 500 V (DMX-bus) item no. 0717-9002: max. 125 V (IE Cat 5) |
---|---|
Nominal voltage | Uo/U 300/500 V (supply conductors) |
Testing voltage | core/core 2000 V |
Current-carrying capacity | acc. to VDE 0298-4 see chapter N „Technical Data“ |
Min. bending radius | for laying and installation (fixed laying): ≤ 12 mm 3 x d/>12 mm 4 x d
for repeated winding action (flexible): 6x d
guided on pulleys (flexible): 7,5 x d |
Temperature range | fixed laying: -50/+90°C flexible application: -40/+90°C
0717-9001 fixed laying: -40/+70°C 0717-9001 flexible application: -40/+70°C
0717-9002 with installation: 0/+50°C 0717-9002 fixed laying: -20/+60°C 0717-9002 flexible application: -20/+60°C |
Halogen-free | acc. to DIN VDE 0472 part 815 and IEC 60754-1 |
Fire performance | flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2 |
Oil resistance | very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 |
Chem. resistance | good against acids, alkalines, solvents, hydraulic liquids, etc. |
Sunlight resistance | very good - enhanced due to black sheath colour |
Tensile strength | with reference to VDE 0298-3 section 7.1 |
Mechanical characteristics | the main mechanical characteristics fulfils by the PUR outer sheath are:
-high tensile strength -high tear strength -high abrasion resistance -high notch resistance |
Absence of harmful substances | acc. to RoHS directive of the European Union |
item no. 0717-9001: max. 500 V (DMX-bus)
item no. 0717-9002: max. 125 V (IE Cat 5)
Uo/U 300/500 V (supply conductors)
core/core 2000 V
acc. to VDE 0298-4 see chapter N „Technical Data“
for laying and installation (fixed laying):
≤ 12 mm 3 x d/>12 mm 4 x d
for repeated winding action (flexible): 6x d
guided on pulleys (flexible): 7,5 x d
fixed laying: -50/+90°C
flexible application: -40/+90°C
0717-9001 fixed laying: -40/+70°C
0717-9001 flexible application: -40/+70°C
0717-9002 with installation: 0/+50°C
0717-9002 fixed laying: -20/+60°C
0717-9002 flexible application: -20/+60°C
acc. to DIN VDE 0472 part 815 and IEC 60754-1
flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2
very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2
good against acids, alkalines, solvents, hydraulic liquids, etc.
very good - enhanced due to black sheath colour
with reference to VDE 0298-3 section 7.1
the main mechanical characteristics fulfils by the PUR outer sheath are:
-high tensile strength
-high tear strength
-high abrasion resistance
-high notch resistance
acc. to RoHS directive of the European Union
Dimensions
item no. |
No. of cores x cross section | Copper figure | Cable weight ≈ |
Tensile strength max. |
min. breaking load of suspension unit | Outer-ø ± 5% | |
---|---|---|---|---|---|---|---|
L07170425 | 4 G 2,50 mm² | 96 kg/km | 157 kg/km | 150 N | 1345 N | 9,7 mm | Send inquiry |
L07170440 | 4 G 4,00 mm² | 153,6 kg/km | 239 kg/km | 240 N | 1690 N | 11,7 mm | Send inquiry |
L07171440 | 14 G 4,00 mm² | 537,6 kg/km | 739 kg/km | 840 N | 3200 N | 20,9 mm | Send inquiry |
L07172040 | 20 G 4,00 mm² | 768 kg/km | 1021 kg/km | 1200 N | 3700 N | 23,3 mm | Send inquiry |
L07172540 | 25 G 4,00 mm² | 960 kg/km | 1318 kg/km | 1500 N | 4200 N | 28,3 mm | Send inquiry |
L07170460 | 4 G 6,00 mm² | 230,4 kg/km | 333 kg/km | 360 N | 1860 N | 13,4 mm | Send inquiry |
L07171360 | 13 G 6,00 mm² | 748,8 kg/km | 1013kg/km | 1170 N | 3400 N | 24,3 mm | Send inquiry |
L07171860 | 18 G 6,00 mm² | 1036,8 kg/km | 1306 kg/km | 1620 N | 6000 N | 25,7 mm | Send inquiry |
L07170470 | 4 G 10,0 mm² | 384 kg/km | 559 kg/km | 600 N | 2300 N | 17,1 mm | Send inquiry |
L07170480 | 4 G 16,0 mm² | 614,4 kg/km | 864 kg/km | 960 N | 2800 N | 21,3 mm | Send inquiry |
L07179001 | 14 G 4,00 + 2 x (2 x 0,25)C mm² | 575,4 kg/km | 794 kg/km | 840 N | 2500 N | 22,4 mm | Send inquiry |
L07179002 | 5 G 16,0 + 4 x 2 x 0,14 mm² | 791,6 kg/km | 1163 kg/km | 1200 N | 3000 N | 26,4 mm | Send inquiry |
L07179013 | 25 G 4,00 mm² | 960 kg/km | 1290 kg/km | 1500 N | 2600 N | min. 25,0 / max. 28,0 mm | Send inquiry |
cross section
max.
of suspension unit