Application
The halogen-free, flexible PE Profibus-DP cable is suitable for a temperature range between -40 / +70°C. It can be laid both fixed and flexible. This Profibus cable has been specially developed for communication between automation systems and decentralised peripheral devices in the field.
Outstanding features
- halogen-free
- good weather resistance
Construction
Conductor | 0,34 mm²: bare copper strands acc. to DIN VDE 0812 1,00 mm²: bare copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5 |
---|---|
Pairwise wrapping | Alu foil, PETP foil |
Insulation | 0,34 mm²: DIN VDE 0819 part 103 (02YI1) 1,00 mm²: PE, 2YI1 acc. to DIN VDE 0207 part 2 |
Colour code | red, green (0,34 mm²); brown, light blue and green-yellow earth wire (1,0 mm²) |
Pairwise screening | tinned copper braiding |
Stranding | in layers |
Sheath material | PE, 2YM1 acc. to DIN VDE 0207 part 3 |
Sheath colour | redlilac (RAL 4001) |
0,34 mm²: bare copper strands acc. to DIN VDE 0812
1,00 mm²: bare copper strands acc. to IEC 60228, EN 60228, VDE 0295, class 5
Alu foil, PETP foil
0,34 mm²: DIN VDE 0819 part 103 (02YI1)
1,00 mm²: PE, 2YI1 acc. to DIN VDE 0207 part 2
red, green (0,34 mm²); brown, light blue and green-yellow earth wire (1,0 mm²)
tinned copper braiding
in layers
PE, 2YM1 acc. to DIN VDE 0207 part 3
redlilac (RAL 4001)
Technical data
Peak operating voltage | max. 350 V |
---|---|
Testing voltage | 1500 V |
Min. bending radius | 12 x d |
Temperature range | fixed laying: -40/+70°C flexible application: -40/+70°C |
Corrosiveness of conflagration gases | in compliance with IEC 60754-2 and EN 50267-2-2 + VDE 0482 part 267-2-2 - no development of corrosive conflagration gases |
For fixed installation | suitable |
For flexible application | suitable |
Application in cable tracks | not recommended |
Weather resistance | good |
Absence of harmful substances | acc. to RoHS directive of the European Union |
max. 350 V
1500 V
12 x d
fixed laying: -40/+70°C
flexible application: -40/+70°C
in compliance with IEC 60754-2 and EN 50267-2-2 + VDE 0482 part 267-2-2 - no development of corrosive conflagration gases
suitable
suitable
not recommended
good
acc. to RoHS directive of the European Union
Dimensions
item no. | Dimension | Outer-ø ± 5% | Copper figure | Cable weight ≈ | |
---|---|---|---|---|---|
L06332341 | 2 x 0,34 mm² | 7,5 mm | 25,8 kg/km | 50 kg/km | Send inquiry |
L06334341 | 2 x 0,34 mm² + 3 x 1,00 mm² | 10,1 mm | 58,8 kg/km | 101 kg/km | Send inquiry |