CATLine SPE C-Track

Single-Pair-Ethernet cable with UL recognition, suitable for cable tracks

Marking for CATLine SPE C-Track: SAB BRÖCKSKES · D-VIERSEN · CATLine SPE C-Track 2xAWG26/7 1777-1630 UL AWM Style 20549 80°C 300V CE

Marking for CATLine SPE C-Track: SAB BRÖCKSKES · D-VIERSEN · CATLine SPE C-Track 2xAWG26/7 1777-1630 UL AWM Style 20549 80°C 300V CE

Application

With the new product series CATLine SPE - Single Pair Ethernet - SAB offers cables for applications in cable tracks, robots and high temperature. With a bandwidth of 1-600 MHz, the cables ensure safe and reliable data transmission. The SPE C-Track Singe-Pair Ethernet cable with UL approval is ideally suited for use in cable tracks. It is highly flexible, PWIS non-critical, oil-resistant, UL-approved and RoHS-compliant.

Outstanding features

  • UL recognition
  • suitable for cable tracks
  • halogen-free
  • very good oil resistance
  • low cabling effort
  • short latency periods
  • small outer diameter
  • PWIS uncritical (PWIS= paint-wetting impairment substances)
  • good against aggressive chemicals

Construction

Conductor

bare copper strands

Insulation

special polymer

Colour code

white-blue

Stranding

twisted to pairs

Inner sheath

SABIX®

Screen

alu foil and tinned copper braiding

Wrapping

non-woven tape

Sheath material

PUR

Sheath colour

green (similar RAL 6018)

Conductor

bare copper strands

Insulation

special polymer

Colour code

white-blue

Stranding

twisted to pairs

Inner sheath

SABIX®

Screen

alu foil and tinned copper braiding

Wrapping

non-woven tape

Sheath material

PUR

Sheath colour

green (similar RAL 6018)

Technical data

Peak operating voltage

max. 90 V

Voltage UL

300 V

Testing voltage

core/core 2000 V

core/screen 2000 V

Min. bending radius

fixed laying: 5 x d

flexible application: 10 x d

continuously flexible: 15 x d

Temperature range VDE

VDE fixed laying: -40°C/+70°C

VDE flexible application: -40°C/+70°C

UL: up to + 80°C

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Oil resistance

very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2

Characteristic impedance

100Ω ± 10Ω, fulfils the electrical and transmission requirements with high frequency

with reference to IEC 61156-12. Bandwidth 1 - 600 MHz.

Absence of harmful substances

acc. to RoHS directive of the European Union

Peak operating voltage

max. 90 V

Voltage UL

300 V

Testing voltage

core/core 2000 V

core/screen 2000 V

Min. bending radius

fixed laying: 5 x d

flexible application: 10 x d

continuously flexible: 15 x d

Temperature range VDE

VDE fixed laying: -40°C/+70°C

VDE flexible application: -40°C/+70°C

UL: up to + 80°C

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Characteristic impedance

100Ω ± 10Ω, fulfils the electrical and transmission requirements with high frequency

with reference to IEC 61156-12. Bandwidth 1 - 600 MHz.

Absence of harmful substances

acc. to RoHS directive of the European Union

Dimensions

item no. Dimension Outer-ø ± 10% Copper figure Cable weight ≈
L177716302 x 26/7 AWG4,6 mm16,9 kg/km29 kg/km Send inquiry
L177712302 x 22/19 AWG5,7 mm22,7 kg/km40 kg/km Send inquiry
item no.
Dimension
Outer-ø ± 10%
Copper figure
Cable weight ≈
L17771630
2 x 26/7 AWG
4,6 mm
16,9 kg/km
29 kg/km
L17771230
2 x 22/19 AWG
5,7 mm
22,7 kg/km
40 kg/km

Other dimensions and colours are possible on request.

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00