SL 891 C

Low capacity combined PUR motor connection cable with overall copper screen 0.6/1 kV

Marking example: SAB BRÖCKSKES · D-VIERSEN · 0891-1415 SL 891 C 4x1,5mm²+(2x1,5mm²) cULus AWM Style 21223 I/II A/B 80°C 1000V FT1 FT2 E172204 CE

Marking example: SAB BRÖCKSKES · D-VIERSEN · 0891-1415 SL 891 C 4x1,5mm²+(2x1,5mm²) cULus AWM Style 21223 I/II A/B 80°C 1000V FT1 FT2 E172204 CE

Application

Outstanding features

  • low capacity construction
  • UL/cUL recognized
  • very good EMC characteristics
  • long service life
  • adhesion-free installation
  • high flexibility
  • suitable for cable tracks
  • halogen-free
  • very good oil resistance
  • PWIS uncritical (PWIS = paint-wetting impairment substance)
  • flexible at low temperatures
  • DESINA® colours

Additional information

  • low capacity solution for your servo drive system

Construction

Conductor

bare copper strands acc. to IEC 60228, VDE 0295, class 6

Insulation

SABIX®

Colour code

Bosch Rexroth

supply cores:

black, number coded 1-3

and a green-yellow earth wire,

control cores: black, number coded 5-8

 

Siemens

supply cores:

core 1: black, (U/L1/C/L+)

core 2: black, (V/L2)

core 3: black, (W/L3/D/L-)

and a green-yellow earth wire

control cores: black BR1, white BR2

Stranding

control cores: twisted to pairs

Wrapping

control cores: alu-foil

Screen

control cores: tinned copper braiding

Wrapping

control cores: foil

Stranding

screened control pairs and supply cores twisted together with fillers in layers

Wrapping

non-woven tape

Screen

tinned copper braiding

Wrapping

non-woven tape

Sheath material

PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 with mat surface

Sheath colour

orange (RAL 2003)

Conductor

bare copper strands acc. to IEC 60228, VDE 0295, class 6

Insulation

SABIX®

Colour code

Bosch Rexroth

supply cores:

black, number coded 1-3

and a green-yellow earth wire,

control cores: black, number coded 5-8

 

Siemens

supply cores:

core 1: black, (U/L1/C/L+)

core 2: black, (V/L2)

core 3: black, (W/L3/D/L-)

and a green-yellow earth wire

control cores: black BR1, white BR2

Stranding

control cores: twisted to pairs

Wrapping

control cores: alu-foil

Screen

control cores: tinned copper braiding

Wrapping

control cores: foil

Stranding

screened control pairs and supply cores twisted together with fillers in layers

Wrapping

non-woven tape

Screen

tinned copper braiding

Wrapping

non-woven tape

Sheath material

PUR, TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2 with mat surface

Sheath colour

orange (RAL 2003)

Technical data

Nominal voltage

supply cores: Uo/U 0.6/1 kV

Peak operating voltage

control cores: max. 350 V

Voltage UL/cUL

1000 V

Testing voltage

supply cores:

core/core 4000 V

core/screen 4000 V

 

control cores:

core/core 2000 V

core/screen 2000 V

Min. bending radius

fixed laying: 5 x d

flexible application: 10 x d

Temperature range

DIN VDE

fixed laying: -50/+90 °C

flexible application: -40/+90°C

cUL: up to +80°C

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, cUL FT1, FT2

Oil resistance

very good - TMPU acc. to EN 50363-10-2 + VDE 0207-363-10-2

Chem. resistance

good against acids, alkalines, solvents, hydraulic liquids etc

Weather resistance

very good

Absence of harmful substances

acc. to RoHS directive of the European Union

Nominal voltage

supply cores: Uo/U 0.6/1 kV

Peak operating voltage

control cores: max. 350 V

Voltage UL/cUL

1000 V

Testing voltage

supply cores:

core/core 4000 V

core/screen 4000 V

 

control cores:

core/core 2000 V

core/screen 2000 V

Min. bending radius

fixed laying: 5 x d

flexible application: 10 x d

Temperature range

DIN VDE

fixed laying: -50/+90 °C

flexible application: -40/+90°C

cUL: up to +80°C

Halogen-free

acc. to IEC 60754-1 + VDE 0482-754-1

Fire performance

flame retardant and self-extinguishing acc. to IEC 60332-1-2 + VDE 0482-332-1-2, cUL FT1, FT2

Chem. resistance

good against acids, alkalines, solvents, hydraulic liquids etc

Weather resistance

very good

Absence of harmful substances

acc. to RoHS directive of the European Union

Abmessungen

item no. Description Dimension Outer-ø Copper figure Cable weight ≈
L089104154 x 1,50 mm² + 2 x (2 x 0,75 mm²)11,4 ± 0,8 mm166,5 kg/km211 kg/km Send inquiry
L089104254 x 2,50 mm² + 2 x (2 x 1,00 mm²)13,1 ± 0,8 mm195,5 kg/km245 kg/km Send inquiry
L089104414 x 4,00 mm² + (2 x 1,00 mm²) + (2 x 1,50 mm²)15,0 ± 0,8 mm303,2 kg/km373 kg/km Send inquiry
L089104614 x 6,00 mm² + (2 x 1,00 mm²) + (2 x 1,50 mm²)17,1 ± 0,8 mm422,9 kg/km497 kg/km Send inquiry
L089104714 x 10,00 mm² + (2 x 1,00 mm²) + (2 x 1,50 mm²)19,3 ± 0,8 mm581,3 kg/km692 kg/km Send inquiry
L089104854 x 16,00 mm² + 2 x (2 x 1,50 mm²)22,9 ± 0,8 mm860,1 kg/km1012 kg/km Send inquiry
L089104904 x 25,00 mm² + 2 x (2 x 1,50 mm²)28,2 ± 0,8 mm1240,8 kg/km1447 kg/km Send inquiry
L089114104 x 1,00 mm² + (2 x 0,50 mm²)9,0 ± 0,8 mm88,2 kg/km120 kg/km Send inquiry
L089114154 x 1,50 mm² + (2 x 1,50 mm²)10,7 ± 0,8 mm150,5 kg/km189 kg/km Send inquiry
L089114164 x 1,50 mm² + (2 x 0,50 mm²)9,5 ± 0,8 mm108,0 kg/km142 kg/km Send inquiry
L089114254 x 2,50 mm² + (2 x 1,50 mm²)12,2 ± 0,8 mm195,5 kg/km244 kg/km Send inquiry
L089114404 x 4,00 mm² + (2 x 1,50 mm²)13,6 ± 0,8 mm262,1 kg/km317 kg/km Send inquiry
L089114604 x 6,00 mm² + (2 x 1,50 mm²)16,3 ± 0,8 mm376,8 kg/km450 kg/km Send inquiry
L089114704 x 10,00 mm² + (2 x 1,50 mm²)18,5 ± 0,8 mm544,0 kg/km657 kg/km Send inquiry
L089114804 x 16,00 mm² + (2 x 1,50 mm²)22,1 ± 0,8 mm797,1 kg/km946 kg/km Send inquiry
L089114904 x 25,00 mm² + (2 x 1,50 mm²)26,2 ± 0,8 mm1170,6 kg/km1354 kg/km Send inquiry
item no.
Description
Dimension
Outer-ø
Copper figure
Cable weight ≈
L08910415
4 x 1,50 mm² + 2 x (2 x 0,75 mm²)
11,4 ± 0,8 mm
166,5 kg/km
211 kg/km
L08910425
4 x 2,50 mm² + 2 x (2 x 1,00 mm²)
13,1 ± 0,8 mm
195,5 kg/km
245 kg/km
L08910441
4 x 4,00 mm² + (2 x 1,00 mm²) + (2 x 1,50 mm²)
15,0 ± 0,8 mm
303,2 kg/km
373 kg/km
L08910461
4 x 6,00 mm² + (2 x 1,00 mm²) + (2 x 1,50 mm²)
17,1 ± 0,8 mm
422,9 kg/km
497 kg/km
L08910471
4 x 10,00 mm² + (2 x 1,00 mm²) + (2 x 1,50 mm²)
19,3 ± 0,8 mm
581,3 kg/km
692 kg/km
L08910485
4 x 16,00 mm² + 2 x (2 x 1,50 mm²)
22,9 ± 0,8 mm
860,1 kg/km
1012 kg/km
L08910490
4 x 25,00 mm² + 2 x (2 x 1,50 mm²)
28,2 ± 0,8 mm
1240,8 kg/km
1447 kg/km
L08911410
4 x 1,00 mm² + (2 x 0,50 mm²)
9,0 ± 0,8 mm
88,2 kg/km
120 kg/km
L08911415
4 x 1,50 mm² + (2 x 1,50 mm²)
10,7 ± 0,8 mm
150,5 kg/km
189 kg/km
L08911416
4 x 1,50 mm² + (2 x 0,50 mm²)
9,5 ± 0,8 mm
108,0 kg/km
142 kg/km
L08911425
4 x 2,50 mm² + (2 x 1,50 mm²)
12,2 ± 0,8 mm
195,5 kg/km
244 kg/km
L08911440
4 x 4,00 mm² + (2 x 1,50 mm²)
13,6 ± 0,8 mm
262,1 kg/km
317 kg/km
L08911460
4 x 6,00 mm² + (2 x 1,50 mm²)
16,3 ± 0,8 mm
376,8 kg/km
450 kg/km
L08911470
4 x 10,00 mm² + (2 x 1,50 mm²)
18,5 ± 0,8 mm
544,0 kg/km
657 kg/km
L08911480
4 x 16,00 mm² + (2 x 1,50 mm²)
22,1 ± 0,8 mm
797,1 kg/km
946 kg/km
L08911490
4 x 25,00 mm² + (2 x 1,50 mm²)
26,2 ± 0,8 mm
1170,6 kg/km
1354 kg/km

Other dimensions and colours are possible on request.

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00