GP 400 SF 28V DC

400 Hz Ground Power supply cable 28 V DC

Marking example: SAB BRÖCKSKES · D-VIERSEN · GP 400 SF 28V DC 6x40,0mm²+14x1,0mm² 3400-9020 CE and continuous meter marking

Marking example: SAB BRÖCKSKES · D-VIERSEN · GP 400 SF 28V DC 6x40,0mm²+14x1,0mm² 3400-9020 CE and continuous meter marking

Application

For the application as fixed supply cable with optimised installation or for a flexible hand-held application without elevated mechanical stress for example mobile GPUs. Excellent flexibility due to smooth core and sheath materials make possible an easy laying and handling.

Outstanding features

  • low capacity insulation
  • extremely flexible and smooth handling
  • also usable as supply cable at the aircraft itself
  • very good installation in narrowest spaces
  • good resistance characteristics also against wear and tear

Construction

Conductor

tinned copper strands, fine wires

Insulation

SABIX®

Colour code

1,0 mm²: black cores with consecutive numbers 1 - 14

40,0 mm²: white cores with consecutive numbers 1 - 3,

black cores with consecutive numbers 1 - 3

Stranding

in layers

Sheath material

PVC

Sheath colour

orange

Conductor

tinned copper strands, fine wires

Insulation

SABIX®

Colour code

1,0 mm²: black cores with consecutive numbers 1 - 14

40,0 mm²: white cores with consecutive numbers 1 - 3,

black cores with consecutive numbers 1 - 3

Stranding

in layers

Sheath material

PVC

Sheath colour

orange

Technical Data

Voltage

28 V DC

Testing voltage

core/core 600 V

Min. bending radius

fixed laying: 4 x d

flexible application: 6 x d

Temperature range

fixed laying: -40/+70 °C

flexible application: -20/+70 °C

Oil resistance

acc. to internal standard

Absence of harmful substances

acc. to RoHS directive of the European Union

Voltage

28 V DC

Testing voltage

core/core 600 V

Min. bending radius

fixed laying: 4 x d

flexible application: 6 x d

Temperature range

fixed laying: -40/+70 °C

flexible application: -20/+70 °C

Absence of harmful substances

acc. to RoHS directive of the European Union

Dimensions

item no. No. of cores x
cross section
Outer-ø Copper figure Cable weight ≈ Ohmic resistance
at 20°C max.
L340090206 x 40,0 mm² + 14 x 1,0 mm²min. 36,0 mm / max. 37,99 mm2438,4 kg/km2910 kg/km40,0 mm²: max. 0,500 Ω/km / 1,0 mm²: max. 20,0 Ω/km Send inquiry
item no.
No. of cores x
cross section
Outer-ø
Copper figure
Cable weight ≈
Ohmic resistance
at 20°C max.
L34009020
6 x 40,0 mm² + 14 x 1,0 mm²
min. 36,0 mm / max. 37,99 mm
2438,4 kg/km
2910 kg/km
40,0 mm²: max. 0,500 Ω/km / 1,0 mm²: max. 20,0 Ω/km

Other dimensions and colours are possible on request.

Highly flexible cables according to your special requirements

Family business for construction and production since 1947

Please send us your inquiry
+49 (0)2162 898-0
Monday to Thursday, 7.30–16.30
Friday, 07.30–15.00